Radiator Air Release Valve Assembly
Radiator Air Release Valve Assembly vs Ordinary Single-Body Radiator Automatic Air Vent Comparison
Ordinary single-body radiator automatic air vent:Single float exhaust head only; does not include a base shut-off valve; to replace the exhaust valve, the radiator's inlet and outlet must be closed and the internal water drained; the system must be depressurized before disassembly is permitted; must be installed vertically; in the event of a leakage fault, the unit must be shut down for repair; simple structure and low cost.
Radiator air release valve assembly:Integrated 2-in-1 design: features a built-in brass isolation shut-off base and a float-type automatic exhaust valve head. The closed base incorporates an internal shut-off valve, allowing the system to operate under pressure without requiring the radiator to be drained; the exhaust valve head can then be directly unscrewed for cleaning, maintenance, or replacement, provided that the exhaust head remains oriented vertically upward. This design combines the advantages of exhaust functionality with online maintainability, while offering higher cost compared to standalone exhaust valves.
|
Item |
Radiator Air Release Valve Assembly (This Product) |
Ordinary Single-Body Radiator Automatic Air Vent |
|
Structure |
Integrated assembly:shut-off isolation base valve + float-type vent head |
Only float-type vent head, NO built-in shut-off base |
|
Installation requirement |
Vent head strictly vertical upward;tilt/horizontal mounting causes leakage / vent failure |
Vent head strictly vertical upward;tilt/horizontal mounting causes leakage / vent failure |
|
Core function |
Automatically discharge entrapped air from radiator;base valve for service isolation |
Only automatic air discharge;no isolation function |
|
Safety boundary |
Air-vent only, CANNOT act as pressure relief safety valve |
Air-vent only, CANNOT act as pressure relief safety valve |
|
Failure risk |
Float / tiny exhaust hole clogged by dirt → continuous dripping |
Float / exhaust hole clogged by dirt → continuous dripping |
|
Typical usage |
Radiator points requiring convenient later-period maintenance;commercial & high-difficult-to-drain heating loops |
Simple residential radiators with infrequent maintenance demand |
Product Overview
Yuanlun radiator air release valve assembly is combined float-type automatic air vent assembly for closed-loop radiator heating hydronic systems. Consists of two core parts:brass shut-off isolation base valve and removable float-type air vent head with EPDM sealing components.
PN16 nominal pressure-rating, working-temperature 5℃-90℃. Under normal operation, float-type vent head automatically releases air accumulated inside radiator;when air is exhausted and water fills vent cavity, buoyancy lifts float to close exhaust hole to prevent water spraying. Built-in base shut-off valve provides isolation function:after closing base valve, technicians can dismount, clean or replace vent head without draining radiator or depressurizing whole local heating circuit.
Critical functional limitation:
- Vent head MUST be kept strictly vertical-upward during installation;tilted or horizontal mounting will break float buoyancy balance, lead to persistent dripping or complete loss of venting function.
- This product ONLY discharges entrapped air. It is NOT safety relief valve and cannot provide over-pressure protection. System over-pressure hazard requires independent safety pressure relief valve.
- Standard EPDM-seal brass variant applies for clean closed-loop heating water / glycol-mixed anti-freeze liquid. FORBIDDEN for steam medium. Rust, sand and solid impurities will easily block tiny exhaust hole and jam float assembly, resulting in continuous water-leakage; dirty-medium systems need upstream filter.
Suitable for residential apartments, office-hotel commercial radiator closed-loop heating systems, especially radiators where draining water for maintenance is inconvenient.
Important note: Installation recommended to be completed by qualified HVAC plumbing technicians. Keep vent head vertical upward at all times during mounting and later-period service.
Key Advantages
- Integrated Shut-off Base-Valve Design: Unique combined assembly of isolation base valve plus float-type vent head. Close base valve to realize local isolation; vent-head can be disassembled, cleaned or replaced under system pressure without draining radiator, greatly reduces maintenance workload.
- Float-Driven Automatic Venting Function: Float-type mechanism automatically exhaust accumulated air inside radiator; after air is fully discharged, float rises with water-level to shut exhaust hole and avoid water leakage, no frequent manual bleeding operation required.
- Compact Radiator-Mount Layout: Optimized compact dimension, perfectly fits standard radiator top air-vent mounting interface DN15-DN25.
- Stable Hydronic-System Compatibility: PN16 pressure-rating, 5-90℃ working range, adapts for water / glycol-mixed anti-freeze closed-loop radiator heating circuits.
Important limitation:Not a pressure-relief safety valve;vent-head must strictly vertical-upward;steam medium prohibited; solid impurities will clog exhaust hole / float assembly.

Specifications
|
Feature |
Description |
|
Place of origin |
China |
|
Brand name |
Yuanlun |
|
Product Name |
Radiator air release valve assembly (shut-off base + float-type vent-head assembly) |
|
Size |
DN15-DN25 |
|
Internal Structure |
Brass isolation shut-off base valve, removable float-type vent-head, float assembly, EPDM O-ring seals, tiny exhaust orifice |
|
Nominal Pressure |
PN16 (1.6 MPa) |
|
Working Temperature |
5℃ ~ 90℃ |
|
Applicable Medium |
Clean closed-loop heating hot-water, glycol-mixed non-corrosive anti-freeze liquid;NOT for steam, strong-corrosion chemical fluid, medium carrying solid rust/sand particles |
|
Operation Mode |
Float automatic air-vent;base-valve manual shut-off for vent-head online maintenance |
|
Installation Requirement |
Vent-head must be strictly vertical upward;tilt / horizontal mounting forbidden |
|
Safety boundary |
Only air-discharge function;CANNOT replace safety pressure-relief valve |
|
Minimum Order Quantity |
1 |
|
Price |
Negotiable |
|
Packing |
Yuanlun standard packing |
|
Payment Terms |
L/C, D/A, D/P, T/T, Western Union,MoneyGram |
|
Delivery Time |
15 Days |
Working Principle
-
Main Components & Function
|
Component |
Core Function |
|
Brass isolation shut-off base valve |
Mount onto radiator top port;manual on-off isolation;after shut-off, vent-head can be serviced under system pressure |
|
Removable float-type vent-head |
Core automatic vent unit, can be screwed off for cleaning/replacement |
|
Plastic float assembly |
Buoyancy sensing element;drops when air accumulates → open exhaust hole;rises when water fills cavity → close exhaust hole |
|
EPDM O-ring seals |
Seal joint between base-valve and vent-head, prevent external water leakage |
|
Tiny exhaust orifice |
Discharge air;easily clogged by rust / solid impurities |
-
Operating Principle
Radiator air release valve assembly combines isolation base valve and float-type automatic air vent:
- Normal venting working state: Base-valve fully open, vent-head strictly vertical-upward. Air separated from heating-water accumulates at radiator top and enters vent-head inner cavity. Air occupies cavity, water-level inside vent-head drops; float sinks by gravity, tiny exhaust orifice opens, entrapped air discharges to atmosphere.
- Auto-close after air exhausted: After all entrapped air is vented, hot-water fills vent-head cavity. Water buoyancy lifts float assembly upwards; float blocks exhaust orifice tightly to stop water from spraying outside, realize automatic air-vent & water-shut-off cycle.
- Maintenance service mode: When vent-head is clogged / malfunctioning, manually close built-in base-valve shut-off position. This isolates vent-head from radiator internal water volume. Now technicians can directly unscrew vent-head, perform cleaning float / exhaust-hole or replace whole vent-head. Radiator remains filled with water, no need to drain radiator or depressurize whole heating circuit. After service finished, screw vent-head back on and reopen base-valve to resume normal vent function.
Three critical operating reminders:
- Vent-head must keep strictly vertical-upward. If tilted or installed horizontally, float cannot work under normal buoyancy balance; symptom: continuous dripping water or completely unable to exhaust air.
- This assembly only exhaust air, CANNOT serve as over-pressure safety relief valve. If system over-pressure risk exists, must install independent safety pressure relief valve on boiler / manifold.
- Tiny exhaust orifice and float gap are very sensitive to rust, sand, scale particles. Solid impurities jam exhaust hole or lock float → permanent dripping leakage. Dirty-medium heating-system must install upstream filter-strainer.
- Steam is strictly forbidden for standard EPDM-seal brass model.
Application Scenarios
-
Residential Radiator Closed-Loop Heating Systems
Use-case: Automatic air vent for radiator top mounting point, especially radiators which are difficult to drain water during maintenance. Project value: Thanks to isolation base-valve, vent-head can be cleaned / replaced without draining radiator water, reduces household maintenance disturbance.
-
Commercial Office / Hotel Centralized Radiator Heating Projects
Use-case: Large quantity radiators in commercial buildings; frequent routine HVAC maintenance requirements. Project value: Online service capability reduces system shutdown duration; avoid large-scale water draining work for hundreds of radiators.
-
Retrofit Renovation Heating-System Projects
Use-case: Renovate old heating circuits; replace old single-body air vents with this assembly for easier later-period service. Project value: Retrofit onto existing standard DN15-DN25 radiator vent port without large-scale pipe modification.
Application exclusion:
- Not for steam pipeline system.
- Cannot replace safety pressure-relief valve for over-pressure protection.
- Medium carrying large amount rust/sand solid particles must add upstream filter-strainer, otherwise vent-head will quickly clog and leak.
Installation Guide
-
Pre-Installation Check
- Confirm assembly DN-size matches radiator top air-vent mounting port thread specification.
- Inspect brass base-valve, removable vent-head, float assembly and EPDM O-ring seals; reject cracked, deformed, float-jammed components.
- Confirm installation layout requirement: vent-head must point strictly vertically upward after mounting; tilt or horizontal orientation is prohibited.
- Clean radiator mounting-thread, remove burr, rust debris; prepare qualified PTFE-tape.
- Dirty-medium project: confirm upstream filter-strainer is configured to protect vent-head exhaust orifice and float.
-
Installation Steps
- Wind PTFE-tape 3-5 clockwise-turns on radiator top mounting thread port.
- Screw the isolation base-valve onto radiator top port; apply wrench torque only on base-valve brass hex flats. Do NOT apply wrench force onto plastic float vent-head.
- Adjust base-valve final position to guarantee vent-head mounting interface points strictly vertically upward.
- Screw float-type vent-head hand-tight onto base-valve output interface; check EPDM O-ring is correctly seated between mating faces.
- Keep base-valve in fully-open working position after assembly finished.
- Fill radiator and whole heating-system with water, perform pressure-testing.
- Observe vent-head: air will automatically exhaust; after air is discharged vent-head stops dripping water. Inspect thread-joint and O-ring mating-face for external leakage.
-
Important Installation Notes
- Installation recommended for qualified HVAC plumbing technicians.
- Vent-head must strictly vertical upward after installation; tilt / horizontal mounting will cause float malfunction, water dripping or no venting.
- Wrench only on brass base-valve hex flats; never apply wrench force on vent-head plastic housing to avoid internal float damage.
- Base-valve is only for maintenance isolation; normal running keep base-valve fully open. Do NOT close base-valve during daily heating operation (air cannot vent).
- Dirty-medium must configure upstream filter-strainer to block rust/sand particles protecting exhaust orifice and float assembly.
- This product is air-vent only; add independent safety relief valve for system over-pressure protection.
- Standard variant not suitable for steam medium.
Maintenance & Troubleshooting
|
Phenomenon |
Probable Root-Cause |
Recommended Solution |
|
Base-valve thread-joint external leakage |
Insufficient PTFE-tape; scratched mating-thread |
Disassemble joint; re-apply brand-new PTFE-tape; replace base-valve if thread damaged |
|
Vent-head mating-face O-ring leakage |
Aged / misplaced EPDM O-ring |
Close base-valve; unscrew vent-head; re-seat or replace brand-new EPDM O-ring |
|
Vent-head keeps continuously dripping water (most common fault) |
1. Vent-head not vertical-upward (tilted installation);2. Rust / scale solid particle clogs tiny exhaust orifice or jams float assembly |
1. Re-adjust base-valve orientation, make vent-head strictly vertical-upward;2. Close base-valve, remove vent-head; clean exhaust-hole and float assembly; heavy-clog replace whole vent-head spare-part |
|
Radiator still stays air-locked, vent-head cannot exhaust air |
1. Base-valve mistakenly closed during normal operation;2. Exhaust orifice fully blocked by dirt |
1. Re-open base-valve to fully-open working-state;2. Isolate, dismount and clean vent-head exhaust hole |
|
Cannot dismount vent-head for maintenance |
Base-valve not fully shut-off; residual system pressure pushes vent-head |
Fully rotate base-valve to shut-off isolation position; release tiny residual air pressure from vent-head before unscrewing |
Routine-Maintenance Suggestion
- Visual inspection for joint leakage & abnormal vent-head dripping: Quarterly during heating-season
- System annual overhaul: Close base-valve, take-down vent-head, clean exhaust-orifice and float assembly, inspect EPDM O-ring ageing condition: Annually before heating-season startup
- Replace clogged / damaged vent-head or aged O-ring spare-parts upon dripping / vent-failure: As-required
- Dirty-medium circuit: Periodically clean upstream filter-strainer to reduce impurity entering vent assembly.
Purchase Considerations
When purchasing radiator air release valve assembly:confirm DN-size DN15-DN25 thread matches radiator top vent port. Clarify project requirement:
This is isolation-base + vent-head combined assembly, allows online vent-head service without radiator draining. If no maintenance-convenience requirement, cheaper single-body radiator air vent is alternative option.
Hard requirement: vent-head must install strictly vertical-upward; confirm radiator mounting port geometry can achieve vertical-up orientation after base-valve mounting.
Functional boundary: Only air-vent, cannot replace safety pressure-relief valve for over-pressure protection.
Medium: clean water/glycol closed-loop heating system; steam, strong-corrosion prohibited; dirty-medium must match upstream filter-strainer.
FAQ
Q: What is radiator air release valve assembly?
A: It is PN16 combined float-type radiator air-vent assembly, consists of brass isolation shut-off base-valve plus removable float-type vent-head. When base-valve is closed, vent-head can be cleaned/replaced under system pressure without draining radiator water; vent-head must strictly vertical-upward installation; only exhaust entrapped air, not safety relief valve. For DN15-DN25 radiator closed-loop 5-90℃ water/glycol heating circuits.
Q: Can I install vent-head tilted or horizontally for space reason?
A: Strictly not allowed. Float relies on vertical buoyancy balance. Tilt / horizontal mounting leads to float abnormal movement, symptom: continuous water dripping or total loss of air-vent function. Must adjust base-valve position to ensure vent-head points straight up.
Q: Can this assembly replace boiler safety pressure-relief valve to protect system over-pressure?
A: Absolutely cannot. This product function is only discharging accumulated air inside radiator. It has zero over-pressure relief capacity. System over-pressure protection needs independent safety relief valve.
Q: What is advantage compare to ordinary single-body radiator air vent?
A: Built-in isolation base-valve: you can close base-valve and remove vent-head for cleaning or replacement without draining radiator water and without heating-circuit depressurization. Ordinary single-body vent must drain radiator whole water before disassembly.
Q: Vent-head keeps dripping water all the time, what is the most likely reason?
A: Top-rank causes: ①vent-head installation tilted not vertical-up; ②rust/scale impurity blocks exhaust small hole or jams float assembly. Operation: close base-valve, take-down vent-head, clean exhaust hole and float; check vertical installation orientation; replace vent-head if severely clogged.
Q: Can standard-variant be used for steam heating system?
A: No, standard EPDM-seal brass model only for 5-90℃ closed-loop water/glycol non-corrosive liquid; steam application requires special high-temperature customized sealing variant.
Q: Do you support sample-order?
A: Yes, MOQ is 1 unit for sample quality-evaluation purpose. Sample-orders are for evaluation only; bulk-project procurement is our primary-business.
Q: What is standard lead-time?
A: 15 working-days after deposit confirmation.
Products Summary
Yuanlun radiator air release valve assembly is PN16 float-type combined air-vent assembly for radiator closed-loop heating-systems, DN15-DN25 size-range. Integrated brass isolation shut-off base-valve and removable float-type vent-head. After closing base-valve, vent-head can be cleaned / replaced under system pressure without draining radiator water, greatly simplifies later-period HVAC maintenance. Vent-head must be installed strictly vertically upward; automatically exhaust entrapped air inside radiator and auto-close exhaust hole to stop water leakage.
Functional boundary:Only air-discharge function, NOT safety pressure-relief valve; tilted / horizontal mounting will cause failure; standard model not for steam; solid impurities easily clog exhaust orifice and float assembly. Standard variant applies for clean 5-90℃ water / glycol-mixed anti-freeze closed-loop radiator heating circuits. Widely-applied in residential apartments, office-hotel commercial centralized radiator heating and heating-system renovation projects. Sample-order supported for pre-project-evaluation, 15-day standard lead-time for worldwide plumbing-HVAC distributors and engineering-contractors.
Factory Information
Zhejiang Yuanlun Valve Co., Ltd. was founded in 2006, formerly known as Yuhuan Guohong Valve Co., Ltd. It is located in Yuhuan, Zhejiang Province, known as the "Valve Capital of China". After nearly two decades of stable development, Yuanlun Valve is a professional manufacturer for HVAC valves integrating R&D, production and sales. Our product portfolio covers floor heating systems, air-conditioning systems, domestic water valves, including ball valves, thermostatic valves, manifolds, check valves, stop valves, filter valves, angle valves, pipe fittings, corrugated pipes and other series.
Hot Tags: radiator air release valve assembly, China radiator air release valve assembly manufacturers, suppliers, factory, Radiator Air Release Valve Assembly, Union exhaust valve three-component assembly

