Press Fitting Elbow

Press Fitting Elbow

Details
Press Tools: Include electric hydraulic crimping tools, manual separate hydraulic press-fit tools, direct-connection hydraulic press-fit tools, electric separate hydraulic press-fit tools, etc.
Category
Press-fit Pipe Fittings
 
Send Inquiry
Description
Technical Parameters

Press Fitting Elbow

 

 

 

 

 

Why Single Press Isn't Always Enough

Press-fit technology has become the standard for thin-wall stainless steel piping. A single press creates one sealing point at each connection - a proven, reliable joint for most applications.

But some installations cannot tolerate any risk of leakage:

  • Concealed piping inside walls or floors - inaccessible after construction
  • High-rise buildings - leak detection and repair costs escalate with height
  • Hospitals and laboratories - water damage risks contamination and downtime
  • Data centers - even minor leakage damages critical equipment
  • Heritage buildings - renovation disruption must be minimized

In these applications, a single sealing point is one too few.

The Yunnl double press elbow addresses this with two independent sealing points at each connection. If the primary seal is compromised - by vibration, thermal cycling, or installation stress - the secondary seal maintains leak-tight performance.

Design Aspect Single Press Double Press (This Product)
Sealing points per end 1 2 (independent)
Redundancy None Full
Leak risk after seal damage Leakage Secondary seal holds
Best for Accessible piping Concealed, critical, high-rise
Inspection requirement Visual + gauge Visual + gauge

 

Product Overview

Yunnl double press elbow is a 90° directional-change fitting for thin-wall stainless steel piping. The fitting features a double press profile at each end - the press tool creates two separate compression zones, each with its own sealing ring.

How the dual seal works: The primary seal is created at the inner compression zone. The secondary seal is created at the outer compression zone. Both seals are independent - damage to one does not affect the other.

Available end connections: Press-fit both ends. 

 

Key Advantages

Dual Sealing Points – Redundant Leak Protection

Two independent sealing points at each connection. Unlike single press fittings, the double press design maintains leak-tight performance even if the primary seal is compromised. This is critical for concealed piping where access after construction is impossible.

  • Suitable for Concealed and Critical Installations

The redundant sealing design makes double press elbows the preferred choice for:

  1. Piping embedded in walls or floors
  2. High-rise building risers
  3. Hospital and laboratory water systems
  4. Data center cooling lines
  5. Heritage building renovations
  • No Open Flame – Fire-Restricted Area Installation

The press-fit connection requires no welding fire on site. This satisfies fire safety management requirements for high-rise buildings, shopping malls, factory workshops, and other fire-restricted areas.

  • 10-Second Installation – No Consumables

Press operation takes under 10 seconds per joint. No welding rod, no flux, no thread tape, no sealant. Sealing rings are pre-installed at the factory.

  • Consistent Joint Quality – Operator Independent

Press-fit joints are tool-calibrated. The press tool delivers the same compressive force on every joint, eliminating operator error as a variable.

  • Corrosion-Resistant 304/316 Stainless

Available in 304 stainless (standard building water) or 316 stainless (coastal, chemical, or high-chloride environments). Material is passivated after forming to restore the chromium oxide layer.

  • Full-Bore Flow Path

The internal diameter matches the pipe diameter. No flow restriction, minimal pressure drop across the fitting.

 

   
   
   
   
 

 

 

14

 

Specifications

Feature Description

Place of origin

China

Brand name

Yunnl

Product Name

Press Fitting Elbow
Angle Options 45° elbow / 90° elbow
Material SUS304 / SUS316 stainless steel (optional)
Surface Finish Pickled / Passivated / Mirror-polished
Sealing Ring EPDM (‑20°C~110°C) / Fluororubber (‑15°C~150°C)
Available Sizes DN15, DN20, DN25, DN32, DN40, DN50
Nominal Pressure PN16 (1.6 MPa)
Working Temperature ‑20°C ~ 110°C (EPDM) / ‑15°C ~ 150°C (FKM)
Applicable Medium Cold water, hot water, heating water, glycol, compressed air, non-corrosive fluids

Minimum Order Quantity

1

Price

Negotiable

Packing

Yunnl standard packing

Payment Terms

L/C, D/A, D/P, T/T, Western Union,MoneyGram

Delivery Time

15 Days

 

Dual-Seal Construction: What Makes It Different

The double press elbow is not simply a single press elbow pressed twice. It is a different fitting design with:

Construction Feature Single Press Double Press (This Product)
Press profile One compression zone Two separate compression zones
Sealing rings One per end Two per end
Fitting length Standard Slightly longer
Jaw type Standard jaw Double press jaw
Installation procedure One press cycle One press cycle (dual profile)
Verification Gauge check Gauge check + visual of both zones

Press Tool Compatibility

Double press elbows require a double press jaw - a jaw with two compression profiles. Standard single press jaws will not create the dual seal. Confirm jaw compatibility before ordering.

Tool Type Compatibility
Battery-powered press tool Yes (with double press jaw)
Electric-hydraulic press tool Yes (with double press jaw)
Manual hydraulic press tool Yes (with double press jaw)
Standard single press jaw

No

 

Press-Fit vs. Threaded vs. Welded

  • Installation Comparison

Factor Press-Fit (This Product) Threaded Welded
Time per joint 10 seconds 5‑10 minutes 15‑30 minutes
Skill required Low (tool operation) Moderate High (certified)
Tools Press tool + jaws Threading machine, wrenches Welder, gas, PPE
Thread tape/sealant Not required Required Not required
Fire risk None None High
Post‑inspection Visual + gauge Visual X‑ray/dye penetrant
Quality consistency Tool‑calibrated Operator‑dependent Operator‑dependent
  • Connection Quality Comparison

Factor Press-Fit Threaded Welded
Leak risk Low Medium Low (if done well)
Corrosion risk Low Medium (thread crevices) Low
Vibration resistance Good Poor (threads loosen) Excellent
Reusability No Limited No

 

Application Scenarios

  • Concealed Piping in Walls and Floors

Use case: Hot and cold water distribution embedded in building structures.
Value: Double sealing points provide redundant protection where access after construction is impossible.

  • High-Rise Building Risers

Use case: Vertical water supply and return risers in tall buildings.
Value: Leak repair costs escalate with building height. Redundant sealing minimizes this risk.

  • Hospital & Laboratory Water Systems

Use case: Potable water, purified water, and process water lines.
Value: Water damage in healthcare facilities risks contamination and operational downtime.

  • Data Center Cooling Lines

Use case: Chilled water supply to server cooling systems.
Value: Even minor leakage damages critical electronic equipment.

  • Heritage & Renovation Projects

Use case: Piping upgrades in occupied or protected buildings.
Value: No open flame and reliable sealing reduce disruption and risk.

  • Fire Protection Systems

Use case: Wet pipe sprinkler branch lines.
Value: No hot work permit required. Fast installation in occupied buildings.

Important: Press-fit fittings are designed for thin-wall stainless steel pipe meeting EN 10312, ASTM A554, or equivalent standards. They are not suitable for gas, steam, or high-pressure pneumatic systems without specific engineering approval.

 

Installation Workflow

  • Tools Required

Tool Purpose
Press tool Battery-powered or hydraulic
Double press jaw Matching the elbow size
Pipe cutter Rotary style - not abrasive wheels
Deburring tool Internal/external chamfering
Depth marker Oil-based marking pen
Go/no-go gauge Verify pressed joint
  • Installation Steps

Step 1 - Pipe Cutting

  1. Use a stainless steel pipe cutter (rotary style)
  2. Do not use grinding wheels
  3. Cut squarely: end face perpendicular to axis (±0.5°)

Step 2 - Deburring

  1. Remove burrs from both inside and outside edges
  2. Sharp burrs can cut or displace the sealing ring
  3. Wipe pipe end clean after deburring

Step 3 - Insertion Depth Marking

  1. Mark the pipe at the socket depth using an oil-based marker
  2. Tolerance: ±2mm

Step 4 - Sealing Ring Inspection

  1. Visually inspect both sealing rings inside the socket
  2. Confirm both are seated evenly

Step 5 - Pipe Insertion

  1. Insert slowly and straight
  2. Push until the marking line aligns with the socket edge
  3. If too tight: moisten with clean water

Step 6 - Pressing Operation

  1. Position the double press jaw over the fitting bulge
  2. Jaw must be perpendicular to the fitting axis
  3. Activate the press tool - squeeze until the jaw fully closes
  4. Do not over-press

Step 7 - Quality Verification

  1. Use a go/no-go gauge to check the pressed joint
  2. Visually confirm: marking line visible, uniform compression at both sealing zones

 

FAQ

Q: What is the difference between a double press elbow and a single press elbow?

A: A double press elbow has two independent sealing points at each connection. A single press elbow has one. The redundant seal in the double press design maintains leak-tight performance even if one seal is compromised.

Q: Do I need a special press jaw for double press fittings?

A: Yes. Double press fittings require a double press jaw with two compression profiles. Standard single press jaws will not create the dual seal.

Q: What pipes are compatible with this double press elbow?

A: Thin-wall stainless steel pipes meeting EN 10312 or ASTM A554. Not suitable for PEX, PERT, copper, or PPR pipes.

Q: What is the pressure rating?

A: PN16 (1.6 MPa / 16 bar).

Q: What is the temperature range?

A: -20°C to 110°C with EPDM seals. Up to 150°C with FKM seals.

Q: What is the difference between 304 and 316 stainless steel?

A: 304 is standard for most building water and HVAC. 316 contains molybdenum for superior chloride resistance - recommended for coastal, high-chlorine, or chemical environments.

Q: Can the connection be disassembled?

A: Press-fit joints are permanent. Disassembly requires cutting the pipe. For serviceable connections, install a union or threaded adapter nearby.

Q: How is correct installation verified?

A: Three methods: marking line visible at socket edge; go/no-go gauge confirms jaw closure; visual inspection shows uniform compression at both sealing zones.

Q: Are samples available?

A: Yes, MOQ is 1 unit.

Q: What is the lead time?

A: 15 working days.

 

Ordering & Wholesale Information

For plumbing distributors, HVAC contractors, mechanical engineers and project purchasers:

  • Sample order: 1 piece minimum for quality and dimension verification
  • Bulk orders: Competitive pricing, flexible payment terms
  • Custom options: Grade (304/316), angle (45°/90°), size, sealing material (EPDM/FKM)
  • Lead time: 15 working days after deposit confirmation
  • Packing: Standard export cartons or branded packaging (customizable for large orders)
  • Payment: L/C, T/T, D/A, D/P, Western Union, MoneyGram

 

Summary

Yunnl double press elbow provides 90° directional change with dual sealing points for redundant leak protection. The double press profile creates two independent seals at each connection - maintaining performance even if one seal is compromised. Available in 304 and 316 stainless steel, DN15-DN50, PN16, -20°C to 150°C. Suitable for concealed piping, high-rise risers, healthcare facilities, and critical water systems. Sample support, 15-day delivery and flexible payment terms.

 

Hot Tags: press fitting elbow, China press fitting elbow manufacturers, suppliers, factory, Press Fitting Tee, Compression-fitting tee

Send Inquiry
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!