Water Hammer Arrester

Water Hammer Arrester

Details
Place of origin: China
Brand name: Yunnl
Product Name:Water hammer arrester
Minimum Order Quantity: 1
Price: Negotiable
Packing:Yunnl standard packing
Payment Terms: L/C, D/A, D/P, T/T, Western Union,MoneyGram
Delivery Time:15 Days
Applicable temperature: 5℃ to 90℃
Category
Automatic Air Release Valve
 
Send Inquiry
Description
Technical Parameters

Water Hammer Arrester

 

Water Hammer Arrester vs Slow-Closing Check Valve Comparison

Water hammer arrester:Specifically designed to absorb and buffer the water hammer pressure shock waves that have already been generated; absorbs the shock by compressing a sealed, pre-filled chamber via a diaphragm; lacks any check or backflow prevention capability and cannot prevent the medium from flowing backward; must be installed in conjunction with a check valve; should be installed as close as possible to the source of the water hammer.

Slow-closing check valve:The core function prevents backflow of the medium; the damping mechanism extends the valve disc closing time, thereby reducing the intensity of water hammer at its source; however, it cannot absorb the substantial pressure shock waves that have already been generated; for high-head, high-impact operating conditions, it is recommended to use this device in conjunction with a water hammer absorber.

Item

Water Hammer Arrester (This Product)

Slow-Closing Check Valve

Core function

Absorb & buffer existing water-hammer pressure surge;NO anti-backflow function

Prevent medium back-flow;slow closing to reduce water-hammer generation

Working mechanism

Diaphragm compresses pre-charged gas chamber, convert shock kinetic energy into gas potential energy

Damping mechanism delays valve-disc closing stroke

Anti-backflow capacity

None,cannot replace check valve

Primary function: shut-off reverse-flow

Installation priority

Close to shock source (pump outlet / fast-closing valve upstream)

Pump outlet for back-flow protection

Stand-alone usage

Not for standalone pump protection;must match check-valve

Can be used alone for general pump circuits

Failure risk

Gas permeation loss → shock-absorbing performance degrades over time

Damping component ageing → closing speed out-of-spec

Typical usage

Mitigate pressure spike caused by fast valve closure / pump trip

Prevent back-flow and reduce initial water-hammer amplitude

 

Product Overview

Yuanlun water hammer arrester is diaphragm-type gas-charged water-hammer shock absorber. Brass housing, built-in isolating diaphragm which separates water contact side and sealed pre-charged gas chamber. Equipped with inflation plug for on-site pressure supplement.

PN16 nominal pressure-rating, working-temperature 5℃-90℃. During normal pipeline operation, it will not obstruct medium flow. When sudden pump stop or fast valve closure generates water-hammer pressure wave, diaphragm compresses gas chamber to absorb impact energy, suppress pipeline pressure surge, reduce pipe vibration and banging noise, protect pipe, valves and pump equipment.

Critical functional limitation:This product ONLY absorbs pressure surge; it CANNOT prevent medium back-flow. It is not a check-valve. For pump systems, water hammer arrester must work together with qualified check-valve (slow-closing / spring-loaded check valve). The pre-charged gas pressure inside chamber shall be set to 50%-70% of system working pressure for optimal damping effect; gas will slowly permeate through diaphragm over long running hours, periodic pressure inspection & re-inflation is required.

Standard variant applies for clean non-corrosive media: cold-hot tap-water, glycol-mixed anti-freeze liquid. Not suitable for steam, strong-corrosion chemical fluid, medium carrying large solid particles. Widely-used for residential-commercial plumbing, HVAC heating-chilled-water hydronic circuits, pump outlet loops, solenoid-valve fast-switching pipelines.

Important note: Installation recommended to be completed by qualified plumbing / HVAC technicians. Install as close as possible to water-hammer generating source. Reserve sufficient service clearance for later gas-pressure inspection and inflation maintenance.

 

Key Features

  • Non-Obstructive Fluid Passage: It does not hinder normal medium circulation. Realize energy conversion to absorb water-hammer impact force, effectively lower pipeline vibration and water-hammer banging noise during pressure-surge events.
  • Maintainable Gas-Chamber Design: Equipped with dedicated inflation plug for chamber pressure checking and supplementary inflation. Service clearance shall be reserved for future maintenance work. Optimal pre-charge pressure: 50%-70% of system working pressure.

Important limitation:No back-flow prevention function;cannot substitute check-valve;gas will gradually permeate, periodic pressure maintenance is mandatory.

 

3

 

Specifications

Feature

Description

Place of origin

China

Brand name

Yunnl

Product Name

Water hammer arrester (diaphragm-type gas-charged shock absorber)

Connection

Male thread connection

Internal Structure

Isolating rubber diaphragm, sealed pre-charged gas chamber, inflation plug, male-thread joint

Nominal Pressure

PN16 (1.6 MPa)

Working Temperature

5℃ ~ 90℃

Recommended Gas Pre-Charge Pressure

50%-70% of system operating pressure

Applicable Medium

Clean cold-hot tap-water, glycol-mixed non-corrosive anti-freeze liquid;NOT for steam, strong-corrosion chemical fluid, medium with large solid particles

Operation Mode

Passive diaphragm-gas-chamber shock absorption;manual inflation plug for periodic pressure top-up

Minimum Order Quantity

1

Price

Negotiable

Packing

Yuanlun standard packing

Payment Terms

L/C, D/A, D/P, T/T, Western Union,MoneyGram

Delivery Time

15 Days

 

Working Principle

  • Main Components & Function

Component

Core Function

Forged brass housing

PN16 pressure-bearing outer shell, male-thread pipeline connection port, inflation plug mounting seat

Isolating rubber diaphragm

Separate pipeline water side and sealed gas-chamber;deform under water-hammer pressure surge to compress gas cushion

Sealed pre-charged gas chamber

Store pre-pressurized inert gas; absorb water-hammer kinetic energy via gas compression;release energy when pressure drops

Inflation plug

Access port for pressure inspection, supplementary gas inflation for gas loss compensation

Male-thread connection port

Thread docking with pipeline near water-hammer source

  • Operating Principle

Yuanlun diaphragm-type water hammer arrester works by gas-cushion energy absorption:

  1. Normal pipeline steady-flow condition:Diaphragm stays at initial position, gas chamber keeps preset pre-charge pressure, device produces negligible flow resistance and does not block medium circulation.
  2. Water-hammer event (pump sudden trip / fast solenoid-valve closure):High-pressure shock wave propagates to arrester; water-side pressure pushes rubber diaphragm to compress sealed gas chamber. Water-hammer kinetic energy is converted into gas compression potential energy, peak pressure surge is suppressed, pipe banging noise and vibration are reduced.
  3. When pressure-surge fades:Compressed gas inside chamber pushes diaphragm back to original position, device returns to standby state for next water-hammer event.

Three critical operating reminders:

NO automatic air vent / exhaust function. It is NOT air release valve; cannot discharge pipeline entrapped air. Need independent automatic air vent if air-venting is required.

NO anti-backflow / check-valve function. It only absorbs pressure spike, cannot stop reverse-flow. Pump circuit must install separate check-valve.

Gas inside chamber will slowly permeate across rubber diaphragm long-term. Pre-charge pressure will drift downwards. Must periodically inspect gas pressure and perform supplementary inflation, otherwise shock-absorbing performance will degrade or completely fail. Optimal pre-charge: 50%-70% of system working pressure.

 

Application Scenarios

  • Water-Supply Pump Outlet Hydronic Circuits

Use-case: Absorb pump-trip induced water-hammer pressure surges on pump outlet pipelines. Project value: Reduce pressure spike damage to pipe joints, fittings and pump seals; must install together with check-valve for complete pump protection.

  • HVAC Heating & Chilled-Water Systems With Fast-Closing Solenoid Valves

Use-case: Shock absorption for branches equipped with high-speed on-off solenoid valves which generate obvious water-hammer banging noise. Project value: Suppress pipeline vibration and noise, protect heat-exchanger and terminal fittings.

  • Residential & Commercial Plumbing Fast-Shut-Off Fixture Loops

Use-case: Water-hammer mitigation for quick-closing tap / appliance supply pipelines (washing-machine solenoid valve branches). Project value: Eliminate pipe knocking noise caused by rapid valve closure.

Application exclusion:

Not for steam, strong-corrosion chemical medium.

Not for medium carrying large solid particles; particles may abrade rubber diaphragm and cause gas-chamber leakage.

Cannot replace check-valve; cannot replace automatic air release valve.

 

Installation Guide

  • Pre-Installation Check

  1. Confirm arrester thread-spec matches pipeline port; confirm system working pressure to calculate target gas pre-charge pressure (50%-70% system pressure).
  2. Inspect brass housing, rubber diaphragm, inflation plug and thread joint; reject cracked, deformed or diaphragm-damaged units.
  3. Confirm installation location: install as close as possible to water-hammer generation source (pump outlet / fast-closing valve upstream).
  4. Reserve sufficient surrounding clearance for future pressure inspection and inflation maintenance; do not fully enclose arrester without service access.
  5. Prepare qualified PTFE-tape for thread sealing; prepare pressure gauge and inflation tool for post-installation gas charging.
  • Installation Steps

  1. Wind PTFE-tape 3-5 clockwise-turns on arrester male-thread port.
  2. Screw arrester onto pipeline tapping point close to shock source; apply wrench torque only on brass housing hex flats. Do NOT apply force onto inflation plug, avoid plug thread fracture and gas leakage.
  3. Complete thread joint tightening; do not apply stress on inflation-plug assembly.
  4. Isolate system pressure, connect pressure gauge & inflation tool to inflation plug; set gas-chamber pre-charge pressure to 50%-70% of system nominal working pressure.
  5. Finish inflation, seal inflation plug; fill and pressurize whole system.
  6. Perform functional test: trigger water-hammer condition (pump stop / fast valve close), verify pipe knocking noise & pressure-surge is mitigated; inspect thread-joint and inflation-plug for gas / water leakage.
  • Important Installation Notes

  1. Installation recommended for qualified plumbing / HVAC technicians.
  2. Mount as close as possible to water-hammer source. Installation far away from shock origin will heavily weaken absorption effect.
  3. Reserve maintenance access; inflation plug must remain accessible for periodic pressure top-up.
  4. Pre-charge gas pressure strictly follow 50%-70% system-pressure rule: too high → poor shock-absorption; too low → diaphragm over-deflection risk, shorten diaphragm service-life.
  5. This arrester has no exhaust function, no check-valve function. Add independent automatic air-vent if venting is needed; add separate check-valve for pump anti-backflow protection.
  6. Medium must be clean; solid particles will abrade rubber diaphragm and cause chamber gas leakage and product failure.

 

Maintenance & Troubleshooting

Phenomenon

Probable Root-Cause

Recommended Solution

Thread-joint water leakage

Insufficient PTFE-tape; scratched mating thread

Disassemble joint; re-apply brand-new PTFE-tape; replace arrester if thread damaged

Inflation plug gas leakage

Plug loose; plug sealing-ring ageing damage

Isolate system pressure; retighten inflation-plug moderately; replace plug sealing-ring spare-part

Water-hammer noise / pressure-surge returns (shock-absorbing failure)

1. Gas-chamber pressure loss by diaphragm permeation;2. Wrong pre-charge pressure (too high / too low);3. Diaphragm abrasion / rupture caused by solid particles

1. Re-check gas-pressure, re-inflate to target 50%-70% system pressure;2. Re-calibrate pre-charge setting;3. If diaphragm ruptured: whole arrester replacement required

Diaphragm premature damage

Excessive pre-charge pressure; solid particle erosion; frequent extreme pressure spike

Re-adjust gas pre-charge; install upstream filter-strainer for dirty-medium; verify system peak pressure within PN16 rating

  • Routine-Maintenance Suggestion

  • Visual inspection for water / gas leakage at thread joint & inflation plug: Quarterly during operating-season
  • Gas-chamber pressure measurement and supplementary inflation: Every 6-12 months (critical pump-circuit recommend every 6 months)
  • Inspect diaphragm condition during system overhaul; replace whole arrester once diaphragm is ruptured: As-required
  • Dirty-medium system: install upstream filter-strainer to block solid particles protecting rubber diaphragm.

 

Purchase Considerations

When purchasing water hammer arrester:confirm thread-spec, PN16 pressure-rating. Clarify project requirement:

It is shock-absorbing device only; not check-valve, not air release valve. Pump loop must additionally order suitable check-valve; add automatic air-vent if pipeline air-venting needed.

Confirm system working pressure for setting pre-charge gas pressure (target:50%-70% system pressure).

Medium must be clean water/glycol non-corrosive liquid; steam / strong-corrosion / particle-laden fluid need customized diaphragm material variant.

Installation position must be close to water-hammer source and reserve inflation-plug maintenance space.

 

FAQ

Q: What is water hammer arrester?

A: It is PN16 diaphragm-type gas-charged water-hammer shock absorber. It absorbs pressure surge generated by pump trip or fast-closing valve by compressing pre-pressurized gas-chamber, reduce pipeline vibration and banging noise. Important limits: it cannot prevent back-flow (not check-valve); it cannot vent entrapped air (not air release valve); gas will permeate over time and requires periodic pressure re-inflation.

Q: Can water hammer arrester replace check-valve on pump outlet?

A: Absolutely cannot. Arrester only absorbs water-hammer pressure wave, has zero ability to stop medium reverse-flow. Pump outlet must still install dedicated spring-loaded / slow-closing check-valve; arrester works as supplementary shock-absorption partner together with check-valve.

Q: Can this product automatically discharge entrapped air inside pipeline?

A: No. Despite website wrong category under Automatic Air Release Valve, water hammer arrester has no air-venting / exhaust function. If pipeline needs air exhaust, you need to install independent automatic air release valve.

Q: What is correct gas pre-charge pressure setting?

A: Optimal pre-charge gas pressure = 50%-70% of system actual working pressure. Pressure out of this range will lead to degraded shock-absorbing performance or accelerated diaphragm damage. Gas will slowly leak through diaphragm, need regular inspection & supplementary inflation.

Q: Why water-hammer knocking noise comes back after several months usage?

A: Most frequent root-cause: rubber diaphragm causes slow gas permeation, gas-chamber pressure drifts away from target range. Need to isolate system, measure chamber pressure and re-inflate to 50-70% system pressure. If re-inflation cannot hold pressure, diaphragm is ruptured and arrester needs full replacement.

Q: What media can standard product adapt to?

A: Working-temperature 5-90℃, PN16; fit for clean cold-hot tap-water, glycol-mixed anti-freeze liquid. Not for steam, strong-corrosion chemical fluid, medium carrying large solid particles.

Q: Do you support sample-order?

A: Yes, MOQ is 1 unit for sample quality-evaluation purpose. Sample-orders are for evaluation only; bulk-project procurement is our primary-business.

Q: What is standard lead-time?

A: 15 working-days after deposit confirmation.

 

Products Summary

Yuanlun water hammer arrester is PN16 diaphragm-type gas-charged water-hammer shock absorber, male-thread connection, working temperature 5-90℃. Built-in isolating rubber diaphragm and inflatable sealed gas-chamber; target pre-charge pressure is 50%-70% of system working pressure. It passively absorbs water-hammer pressure surges caused by pump sudden stop or fast-closing valves, suppress pipeline pressure peak, reduce vibration and knocking noise.

Functional boundaries:It is only shock-absorption accessory; no anti-backflow check-valve function; no automatic air exhaust function; gas will permeate over long runtime requiring periodic pressure inspection and supplementary inflation. Standard variant applies for clean water/glycol non-corrosive hydronic circuits. Widely-applied for pump outlet loops, HVAC solenoid-valve branches, residential-commercial plumbing fast-shut fixture pipelines. Sample-order supported for pre-project-evaluation, 15-day standard lead-time for worldwide plumbing-HVAC distributors and engineering-contractors.

 

Factory Information

Zhejiang Yuanlun Valve Co., Ltd. was founded in 2006, formerly known as Yuhuan Guohong Valve Co., Ltd. It is located in Yuhuan, Zhejiang Province, known as the "Valve Capital of China". After nearly two decades of stable development, Yuanlun Valve is a professional manufacturer for HVAC valves integrating R&D, production and sales. Our product portfolio covers floor heating systems, air-conditioning systems, domestic water valves, including ball valves, thermostatic valves, manifolds, check valves, stop valves, filter valves, angle valves, pipe fittings, corrugated pipes and other series.

 

Hot Tags: water hammer arrester, China water hammer arrester manufacturers, suppliers, factory, automatic air release valve, Water Hammer Arrester, Water hammer eliminator, Side - mounted automatic air vent valve

Send Inquiry
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!