Side Type Automatic Air Release Valve
The Hidden Impact of Trapped Air in Hydronic Circulation Systems
Air trapped inside closed-loop heating and cooling piping is one of the most common yet frequently overlooked root causes that degrade system performance. If accumulated air cannot be properly vented, it will trigger a series of operational failures:
- Flow starvation: Air pockets block water circulation inside pipes, lowering heat transfer efficiency and creating cold zones on radiators and underfloor heating circuits.
- Pump cavitation: Entrained air flows through circulation pumps, generating noise and vibration, accelerating wear on pump impellers and shortening pump service life.
- Accelerated corrosion: Air contains oxygen. When oxygen mixes with circulating water, oxidation occurs on steel, copper and brass piping components. Sludge will gradually form and eventually lead to premature system breakdown.
- Acoustic complaints: Trapped air creates gurgling and water hammer noise, which is unacceptable for building occupants in both commercial and residential projects.
- Unstable pressure readings: Air pockets cause pressure gauge fluctuation, resulting in unnecessary on-site maintenance service calls.
The reliable solution is continuous air removal at pipeline high points. Yunnl side mounted automatic air release valve continuously exhausts accumulated air automatically, eliminating these system risks from the source, without regular manual intervention.
Product Overview
Yunnl side-mounted automatic air release valve, also referred to as air vent valve, air eliminator or degassing valve, is a fully mechanical float-operated device designed to release trapped air within closed-loop fluid piping systems.
This valve is installed at pipeline high points, the natural gathering zone for free air. When air volume inside the valve reaches the preset threshold, the valve opens to vent gas. After air exhausts and liquid fills the valve chamber, the valve will close automatically.
Different from manual bleed valves which require periodic operator inspection and manual opening, our side type air release valve works autonomously. Its internal float linkage responds only to liquid level inside valve body. No external power supply, control modules or sensors are required for normal operation.
Core Performance Advantages
-
Uninterrupted Automatic Operation
Once installed, the valve needs zero manual operation. The float mechanism runs continuously and responds whenever air accumulates inside the pipeline. It cuts maintenance labour cost and removes human oversight risks associated with traditional manual bleed valves.
-
No Electrical Power & Extra Controls
This valve adopts pure mechanical structure, with no solenoid, motor or controller. It delivers inherent working reliability, and there is no risk of venting failure caused by power outage. Field installation does not need electrical wiring or control panel integration.
-
Rapid Air Exhaust Response
The float linkage is precisely calibrated to open the exhaust orifice at the early stage of air accumulation. Equipped with standard large orifice design (>2.0mm), it discharges air quickly and prevents air from flowing downstream into heat exchangers and circulation pumps.
-
Bubble-Tight Leak-Free Sealing
Float and linkage assembly ensures positive closure of exhaust orifice once liquid returns. Sealing gasket options are EPDM or FKM(Viton), maintaining bubble-tight sealing through thousands of working cycles. Every valve passes factory sealing integrity testing before shipment.
-
Corrosion Resistant Internal Construction
Float material is optional stainless steel or high-temperature resistant plastic, selected for compatibility with different circulating working fluids. With properly matched medium and temperature, internal components will not suffer galvanic corrosion.
-
High-Point Air Removal Efficiency
Mounted at the highest position of fluid systems, the valve captures more than 95% of free air inside the circuit. Multiple valves can be fitted at several high points including riser tops, coil connections and pump discharge sections, to maximise overall air elimination efficiency.



| Feature | Description |
|
Place of origin |
China |
|
Brand name |
Yunnl |
|
Product Name |
Side Type Automatic Air Release Valve |
| Body Material | Forged brass |
| Seal Material | EPDM / Viton (FKM) |
| Nominal Pressure | PN16 (1.6 MPa) |
| Working Temperature | -10°C ~ 110°C (EPDM) / -10°C ~ 150°C (FKM) |
| Working Medium | Water, glycol mixtures, non-corrosive fluids |
| Exhaust Orifice | >2.0mm (standard) |
| Crack Pressure | <0.02 MPa |
|
Size |
DN25 |
|
Minimum Order Quantity |
1 |
|
Price |
Negotiable |
|
Packing |
Yunnl standard packing |
|
Payment Terms |
L/C, D/A, D/P, T/T, Western Union,MoneyGram |
|
Delivery Time |
15 Days |
Comparison: Side-Mounted Air Release Valve vs. Manual Bleed Valve
| Feature | Automatic Air Release Valve (This Model) | Manual Bleed Valve |
|---|---|---|
| Operation Mode | Fully automatic, self-venting | Manual opening required by site operator |
| Maintenance Requirement | Maintenance-free, no regular operator attention | Periodic manual bleeding required; easy to be neglected |
| Air Removal Performance | Continuous venting, releases air as it accumulates | Intermittent air release, only works when manually opened |
| Sealing Reliability | Float-controlled mechanical positive closure | Operator-controlled sealing, depends on manual tightening |
| Recommended Installation | System high points | Point-of-use positions such as radiators and coils |
| Total Cost | Higher upfront cost, lower long-term labour cost | Lower initial purchase cost, higher lifetime maintenance labour cost |
| Suitable Application | Large hydronic systems, high points difficult to access | Individual radiators, easy-to-reach terminal fixtures |
Application Scenarios
Our side type automatic air release valve is widely adopted in closed fluid circulation projects for commercial, residential and industrial sectors:
-
HVAC Chilled & Hot Water Systems
- Chiller and boiler plant headers
- Air separator vessel connections
- Fan coil unit supply risers
- Heating and cooling distribution mains
-
Radiant Floor Heating Systems
- Manifold assembly high-point air venting
- Supply and return pipeline air pocket elimination
- Boiler bypass and mixing loops
-
Solar Thermal Systems
- Collector array high points
- Hot water storage tank connections
- Closed glycol circulation loops
-
Commercial & Building Plumbing
- Domestic water service risers
- Fire sprinkler piping systems
- Water storage tank air venting
-
Industrial Fluid Circulating Systems
- Cooling tower water circuits
- Heat exchanger piping networks
- Industrial process water loops
Step-by-Step Installation Guide
-
Location Selection
Locate the highest point of target pipeline segment, as air naturally rises to the highest elevation. Install the valve vertically, with inlet connection pointing downward and connected to horizontal or upward-sloping pipe tee. The valve body extends sideways in horizontal orientation. Mount the valve on the top quarter of pipe circumference (pipe top area), not pipe side or pipe bottom. "Side type" describes the valve outlet orientation, not pipe tapping position. Avoid installation close to pump discharge; flow turbulence in this area may trigger abnormal float movement.
-
Installation Procedures
Prepare connection point
Weld or thread a tee fitting on the selected high point of pipe. Thoroughly clean internal threads to remove dirt, metal chips and seal debris, preventing contamination to float mechanism.
Apply thread sealant
Wrap PTFE tape (3-4 rounds, clockwise) on male thread of pipe tee. Do NOT apply PTFE tape to valve female thread; tape fragments may enter valve chamber and jam float assembly.
Mount the valve
Screw valve onto tee fitting and tighten by hand first. Rotate valve body so exhaust port faces upward or slightly upward, to ensure gas flows smoothly to exhaust orifice. Use wrench with moderate torque for final tightening. Do not over-tighten, forged brass body may crack under excessive torque.
Connect exhaust outlet
Route exhaust port to drain line. For indoor installation, connect to drip tray or condensate pipe. For systems with fluid thermal expansion, ensure drain line will not create siphon effect that siphons liquid out of valve chamber.
Verify working status
After filling and pressurising the whole system, observe valve for several minutes. Audible air discharge should be heard, followed by complete sealing without water dripping. If no air exhausts, check pipeline blockage, wrong installation orientation or insufficient system working pressure.
On-Site Troubleshooting Guide
| Problem | Likely Cause | Solution |
|---|---|---|
| Valve continuously leaks water | Float stuck at open position / damaged sealing gasket / debris trapped inside exhaust orifice | Shut off isolation valve, remove valve, inspect and clean float chamber. Replace gasket if damaged. |
| Valve fails to vent trapped air | Float stuck at closed position / blocked orifice / incorrect installation orientation | Dismantle and clean float linkage; confirm exhaust port is installed facing upward. |
| Valve chatters or vibrates | High flow velocity at connection point / float oscillation | Relocate valve away from pump discharge or high flow velocity sections; reserve adequate straight pipe on upstream side. |
| No air discharged, gurgling noise remains | Undersized valve for system / insufficient air vents installed at high points | Confirm correct valve sizing; install extra air release valves at other pipeline high points. |
| Seal premature wear | Working temperature exceeds seal rating / fluid chemical incompatibility | Check actual working temperature; upgrade to FKM seals if required. |
FAQ
Q: Where should I install an automatic air release valve?
A: Automatic air release valves must be mounted at the highest points of closed fluid pipelines, such as pipe riser tops, manifold high points, boiler header outlets. Air naturally accumulates at high elevation positions.
Q: Will this valve work with glycol-based heating fluid?
A: Yes. The valve is compatible with water-glycol mixtures, common in solar thermal and low-temperature HVAC systems. Select proper seal material (EPDM / FKM) according to glycol concentration and working temperature.
Q: What is the difference between this air vent and the manual bleed valve on a radiator?
A: This side-mounted automatic air release valve is designed for pipeline high points, working continuously without manual operation. Manual bleed valves are terminal fittings installed on radiators or fan coils, requiring manual opening by operators on a regular schedule. These two products can be used together in one hydronic system for full air elimination.
Q: Can this valve be installed outdoors?
A: Outdoor installation is available with freeze protection measures. If the pipeline may experience freezing temperatures, add insulation or heating trace to prevent liquid inside valve chamber from freezing and damaging internal components.
Q: How do I know if the valve is working correctly?
A: After system filling and pressurisation, listen for intermittent air exhaust sound. Once air is fully vented, the valve should seal tightly without water dripping. Continuous dripping or no air release indicates abnormal status, refer to troubleshooting table.
Q: Can I disassemble the valve for cleaning without isolating the system?
A: No. You must close upstream isolation valve and depressurise the pipeline before removing the valve, to avoid fluid ejection and safety hazards.
Q: What is the minimum operating pressure for this valve?
A: The crack pressure of this DN25 side type automatic air release valve is less than 0.02 MPa. It can work under low pressure closed hydronic systems.
Hot Tags: side type automatic air release valve, China side type automatic air release valve manufacturers, suppliers, factory, automatic air release valve, Water Hammer Arrester, Water hammer eliminator, Side - mounted automatic air vent valve