Stainless Steel Flow Meter Manifolds
Introduction
The Stainless Steel Manifold with Flow Meter is a high‑efficiency hydraulic module that integrates flow distribution, collection, and monitoring functions. Designed for fluid‑handling applications such as central air‑conditioning, boiler circulation, industrial cooling, and hot‑water systems, it features a precision‑cast stainless‑steel structure combined with high‑accuracy mechanical or digital flow meters. This product enables visual flow regulation and dynamic balancing of each branch circuit, significantly improving hydraulic distribution efficiency, energy utilization, and operational stability in multi‑loop systems.
Key Advantages
◆ Precise Hydraulic Distribution & Real‑Time Monitoring
• Each branch is equipped with an adjustable valve and flow meter (±3% accuracy) for independent setting and real‑time monitoring
• Transparent sight window or digital display provides clear visibility of flow rates and cumulative data per circuit
◆ Energy Savings & Operational Cost Reduction
• Return‑water recirculation design reduces system temperature differentials, lowering boiler/chiller cycling frequency
• Overall pressure loss is about 25% lower than traditional dispersed valve arrangements, saving pumping energy
◆ Outstanding Durability & Environmental Adaptability
• 304/316 stainless‑steel integral forging provides corrosion and scale resistance, suitable for high‑chloride water
• Operating temperature range: ‑10 °C to 120 °C, compatible with high‑temperature hot water and low‑temperature cooling media
◆ Easy Installation & Maintenance
• Factory‑preassembled with standardized connections (G/G or flanged options), reducing on‑site work by 60%
• Modular design allows single‑circuit maintenance without affecting overall system operation
◆ Intelligent System Upgrade Potential
• Optional electronic flow sensors, temperature sensors, and actuators for integration into building automation systems (BAS)
• Supports communication protocols such as Modbus and BACnet for remote monitoring and automatic balancing
Working Principle
♦ Flow Distribution Phase
• Main‑line fluid enters the distribution chamber via the supply header
• Each branch regulating valve distributes flow according to the set opening, with real‑time feedback from the flow meter
• If a branch's demand changes, the valve can be adjusted immediately without affecting other branches
♦ Flow Collection & Recirculation Phase
• Return water from all branches converges in the collector and returns to the main line after passing through temperature and pressure monitoring points
• The system can automatically adjust supply temperature or flow based on return‑water temperature to achieve dynamic thermal balance
♦ System Balancing & Protection Mechanisms
• Built‑in pressure‑reducing and safety valve options prevent damage to terminal equipment from sudden pressure changes
• Optional automatic air vents and drain valves keep the system clean and stable

Technical Specifications
| Item | Specifications |
|---|---|
| Body Material | Body: 304/316 stainless steel (forged one‑piece) Seals: EPDM/FKM (temperature range: ‑20 °C to 150 °C) |
| Pressure Rating | Design pressure: 1.6 MPa Test pressure: 2.4 MPa |
| Temperature Range | Continuous operation: ‑10 °C to 120 °C Short‑term peak: 130 °C (≤1 hour) |
| Flow Meter Range | Mechanical: 0.5–10 L/min (per circuit) Electronic: 0.2–15 L/min (programmable) |
| Connection Sizes | Main header: DN32–DN100 (1¼"–4") Branch ports: DN15–DN25 (½"–1") |
| Accuracy Class | Mechanical flow meter: ±3% FS Electronic flow meter: ±1.5% FS |
| Optional Accessories | Pressure gauge (0–1.6 MPa), thermometer (‑20 °C to 150 °C), automatic air vent, drain valve, electric actuator |
| Certifications | ISO 9001, PED 2014/68/EU (optional), potable‑water contact approvals (ACS/KTW) |
Installation & Commissioning Guidelines
• Zoned flow control in commercial‑building central air‑conditioning water systems
• Multi‑building flow distribution and metering in district heating/cooling stations
• Parallel water supply for multiple equipment in industrial circulating‑cooling systems
• Multi‑loop parallel connections in solar thermal or heat‑pump systems
• Precise distribution of process cooling water for laboratory equipment or production lines
Typical Applications
1.Flush pipelines before installation to ensure no welding slag or debris enters the manifold
2.Install according to the flow‑direction arrow; keep flow meters horizontal or vertically upward
3.During initial commissioning, adjust each branch valve to the design flow rate sequentially and record the initial values
4.Periodically (recommended quarterly) check that flow‑meter readings are normal and clean the strainer (if equipped)
5.Drain the system fluid during long‑term shutdowns to avoid freeze damage or static corrosion
Hot Tags: stainless steel flow meter manifolds, China stainless steel flow meter manifolds manufacturers, suppliers, factory, Intelligent hydronic manifold, tainless steel water distributor, Stainless Steel Manifolds, Intelligent Floor Heating Manifold, Forged Integrated Ball Valve Floor Heating Manifold, Manifold with integrated flowmeter