MF Manual Angle Aluminum-Plastic Pipe Radiator Valve

MF Manual Angle Aluminum-Plastic Pipe Radiator Valve

Details
Place of origin: China
Brand name: Yunnl
Product Name:MF Manual Angle Aluminum-Plastic Pipe radiator Valve
Size:DN15-DN50
Minimum Order Quantity: 1
Price: Negotiable
Packing:Yunnl standard packing
Payment Terms: L/C, D/A, D/P, T/T, Western Union,MoneyGram
Delivery Time:15 Days
Applicable temperature: 5℃ to 90℃
Category
Manual Radiator Valve
 
Send Inquiry
Description
Technical Parameters

MF Manual Angle Aluminum-Plastic Pipe Radiator Valve

 

MF Manual Angle Aluminum-Plastic Pipe Radiator Valve vs MF Manual Straight Radiator Valve Comparison

MF manual straight radiator valve adopts straight-through flow-passage, suitable for pipelines arranged in co-axial straight-line, mainly for straight-inlet radiator installation scenarios.

MF manual angle aluminum-plastic pipe radiator valve is 90-degree angular-flow-passage variant, specially equipped with compression-type union connection structure for aluminum-plastic composite pipe. It changes medium flow-direction by 90°, perfectly matches floor-riser aluminum-plastic pipe layout for radiators, saves installation space; no extra transition adapter is needed for aluminum-plastic pipe docking. It is a manual regulating valve without auto-temperature-sensing capsule, requiring manual knob operation to adjust hot-water flow-rate.

Item

MF Manual Angle Aluminum-Plastic Pipe Radiator Valve (This Product)

MF Manual Straight Radiator Valve

Flow-passage form

90° angle-type angular flow-channel

Straight-through inline flow-channel

Pipe connection

Compression union joint for aluminum-plastic composite pipe

Thread-only connection

Layout adaptation

Floor-riser pipe entering radiator, narrow corner installation

Co-axial straight-line pipeline layout

Auxiliary adapter

No extra adapter required for aluminum-plastic pipe

Need extra transition fitting for aluminum-plastic pipe

Regulation mode

Manual knob adjust screw-lift core

Manual knob adjust screw-lift core

Auto-thermostat

None, pure manual regulation

None, pure manual regulation

Typical usage

Radiator connected with aluminum-plastic pipe rising from floor

Straight-in radiator pipeline layout

 

Product Overview

Yuanlun MF manual angle aluminum-plastic pipe radiator valve is brass-bodied angle-type manual heating regulating valve. It adopts 90-degree angular flow-passage and compression-type union joint specially designed for aluminum-plastic composite pipe. Internal screw-lift valve-core converts knob rotary motion into linear displacement to adjust hot-water flow-rate, realizing manual adjustment of radiator heat-output.

PN16 nominal pressure-rating, working-temperature 5℃-90℃. Compact angle-shape structure adapts space-limited radiator-corner installation. It is widely-used for household radiators, floor-heating and commercial building centralized-heating systems with aluminum-plastic pipe piping.

Important note: Installation recommended to be completed by qualified HVAC plumbing technicians. This is manual regulating valve without automatic temperature-sensing function. Compression union nut cannot be over-torqued; excessive force will damage aluminum-plastic pipe outer-wall. Confirm medium flow-direction mark on valve-body before installation.

 

Key Advantages 

  • Easy Operation: The MF manual angle aluminum-plastic thermostatic valve features a simple and user-friendly design, allowing users to easily adjust the temperature, making it highly suitable for home use.
  • High Durability: This thermostatic valve is manufactured using high-quality brass material, endowing it with excellent pressure and temperature resistance properties.
  • Wide Range of Applications: The MF manual angle aluminum-plastic thermostatic valve is compatible with various media, such as water, and is suitable for regulating heating systems in diverse settings, including homes, offices, and more.

 

3

Specifications

Feature

Description

Place of origin

China

Brand name

Yunnl

Product Name

MF Manual Angle Aluminum-Plastic Pipe Radiator Valve

Size

DN15-DN50

Valve-Core Structure

Screw-lift regulating valve-core

Connection Mode

Angle-type body + compression union joint for aluminum-plastic composite pipe

Adjustment Part

Ergonomic manual operation knob

Thread Standard

ISO as default; G-type / NPT customizable

Nominal Pressure

PN16 (1.6 MPa)

Working Temperature

5℃ ~ 90℃

Applicable Medium

Heating hot-water, glycol-mixed anti-freeze non-corrosive heating medium

Operation Mode

Manual knob rotation adjust valve-core opening; compression union for aluminum-plastic pipe connection

Minimum Order Quantity

1

Price

Negotiable

Packing

Yuanlun standard packing

Payment Terms

L/C, D/A, D/P, T/T, Western Union, MoneyGram

Delivery Time

15 Days

 

Working Principle

  • Main Components & Function

Component

Core Function

90-degree angle brass valve-body

Change heating-medium flow-direction, mark medium flow-arrow; bear system pressure

Compression union joint

Clamp and seal aluminum-plastic composite pipe outer-wall

Screw-lift valve-core assembly

Transform knob rotary motion into linear lifting displacement to change flow-passage opening

Manual adjustment knob

Operate opening-degree setting for flow-regulation

Stem packing / sealing-gland

Prevent medium seepage from valve-stem position

  • Operating Principle

  1. Heating-medium flows in according to arrow-marked direction on angle-valve-body.
  2. Rotate manual adjustment knob; rotary motion drives screw-lift valve-core to perform linear up-and-down movement.
  3. Clockwise rotation reduces opening, lowers hot-water flow-rate to decrease radiator heat-output; counter-clockwise rotation enlarges opening to increase heat-output.
  4. Aluminum-plastic composite pipe is reliably locked and sealed by compression union joint, completing pipeline connection.
  5. Realize manual single-radiator flow-setting and heating-system hydraulic balancing.
  6. Operating reminder: No built-in thermal-sensor capsule. It cannot realize automatic constant-temperature; manual re-adjustment is required when heat-demand changes.

 

Application Scenarios

  • Residential Household Heating Systems

Use-case: Radiator terminal regulation for projects adopting floor-rising aluminum-plastic composite pipe. Project value: Angle-type structure adapts narrow-space corner installation; special compression joint simplifies aluminum-plastic pipe docking without extra adapters.

  • Office & Commercial Building Heating Systems

Use-case: Branch-circuit flow regulation for centralized-heating radiator loops in offices and commercial premises. Project value: Realize zone-by-zone manual flow-balancing for multi-room commercial-building heating-systems.

  • HVAC Engineering Retrofit Projects

Use-case: Replacement / new-installation regulating valves for existing aluminum-plastic-pipe heating-network renovation. Project value: Directly match original aluminum-plastic-pipe pipeline, reduce transition-fitting count for renovation-works.

 

Installation Guide

  • Pre-Installation Check

  1. Confirm valve DN-size matches aluminum-plastic pipe outer-diameter; verify valve-body medium-flow-direction arrow marking.
  2. Inspect brass angle-body, screw-lift valve-core, compression union parts and adjustment knob; reject cracked or damaged components.
  3. Square-cut aluminum-plastic pipe-end, fully remove burr and sharp edges on pipe outer-wall.
  • Installation Steps

  1. Slip compression-nut and compression-ferrule onto processed aluminum-plastic pipe-end. Fully insert pipe into valve-body union seat.
  2. Tighten compression-union nut evenly in diagonal sequence. Do NOT apply excessive torque to avoid crushing aluminum-plastic pipe outer-layer.
  3. Confirm medium flows consistent with arrow-mark on valve-body.
  4. Finish assembly, rotate knob to test full-range open-close stroke, confirm valve-core moves smoothly without jamming.
  5. Fill system with water and perform pressure-test; inspect compression-union joint and valve-stem position for leakage.
  6. Complete initial commissioning, set knob opening-degree for heating-system hydraulic balancing.
  • Important Installation Notes

  1. Installation recommended for qualified HVAC plumbing technicians.
  2. Strictly follow valve-body flow-direction arrow; reverse-direction mounting will degrade regulating-performance.
  3. Diagonal-pattern tightening for compression-union nut; prohibit over-torque which will damage aluminum-plastic composite pipe.
  4. Do not apply wrench-force onto plastic adjustment knob, which will cause knob fracture.

 

Maintenance

  • Regular Inspection and Cleaning: Regularly inspect the operating condition of the valve to ensure it functions properly.
  • Lubrication Maintenance: Apply lubricant to the valve stem threads and valve stem actuator to extend the service life of the valve.
  • Anti-Corrosion Treatment: For components prone to rusting, such as the valve stem and machined surfaces of the valve body, regularly apply anti-rust oil for protection. The warehouse where valves are stored should be kept clean and dry to prevent moisture and corrosion.
  • Packing Maintenance: The packing is a critical component for valve sealing. Regularly inspect and replace aged packing to ensure the sealing performance of the valve.
  • Correct Installation: During installation, ensure that the flow direction of the valve aligns with the flow direction of the medium. Tighten the connecting components in a diagonal pattern to prevent leaks caused by uneven stress distribution.
  • Avoid Excessive Use: Do not frequently open and close the valve. Minimize unnecessary operations to extend the service life of the valve.

 

Maintenance & Troubleshooting

Phenomenon

Probable Root-Cause

Recommended Solution

Compression-union joint leakage

Pipe-end burr; insufficient union-nut pre-load; damaged compression-ferrule

Disassemble; re-process pipe-end; replace brand-new ferrule; perform diagonal-pattern retightening

Valve-stem seepage

Aged packing / stem-sealing parts

Isolate system pressure; replace stem-packing spare-parts

Knob rotation stiff / valve-core jamming

Scale, heating-system sludge enter valve-inner-cavity

Flush heating-loop; disassemble and clean valve-stem and screw-lift valve-core; apply qualified lubricant

Cannot fully shut-off flow

Impurity jammed on valve-core sealing-face

Disassemble, clean sealing-face; replace valve-core if sealing-surface is scratched

Routine-Maintenance Suggestion

  • Visual inspection for union-joint and stem-position leakage: Quarterly during heating-season
  • Execute full-stroke open-close operation before each heating-season startup: Annually
  • Replace aged stem-packing and compression-ferrule upon sealing-failure: As-required

 

Purchase Considerations

When purchasing MF manual angle aluminum-plastic pipe radiator valve, confirm nominal-size matches outer-diameter of aluminum-plastic composite pipe. Distinguish angle-type versus straight-type according to on-site radiator-pipeline layout. Confirm project demands: this product is manual regulating-valve without auto-thermostat capsule; select automatic thermostatic radiator valve if constant-temperature auto-control is required.

 

FAQ

Q: Can this angle type manual valve be used as full isolation shut off valve for radiator replacement?

A: It can realize basic shut off function, but main function is flow regulation. For reliable isolation during radiator maintenance, it is recommended to be matched with independent lock shield shut off valve.

Q: Can I install the valve against the arrow mark flow direction?

A: Not recommended. Reverse mounting will deteriorate regulating precision and may increase jamming risk of valve core. Install strictly following valve body medium flow arrow.

Q: Can standard variant be used for steam heating system?

A: Standard model suits liquid phase heating hot water within 5-90℃. Steam working condition needs special high temperature resistant packing and sealing parts specified while ordering.

 

Products Summary

Yuanlun MF manual angle aluminum-plastic pipe radiator valve is brass angle-type manual heating regulating-valve with compression union joint for aluminum-plastic composite pipe. PN16 pressure-rating, DN15-DN50 size-range. 90-degree angular flow-passage, screw-lift valve-core structure for manual flow-regulation. Compact structure fits narrow-space floor-riser radiator installation scenarios. Widely-applied for household radiators, office and commercial centralized-heating HVAC projects adopting aluminum-plastic composite pipe. Sample-order supported for pre-project-evaluation, 15-day standard lead-time for worldwide plumbing-HVAC distributors and engineering-contractors.

 

Factory Information

Zhejiang Yuanlun Valve Co., Ltd. was founded in 2006, formerly known as Yuhuan Guohong Valve Co., Ltd. It is located in Yuhuan, Zhejiang Province, known as the "Valve Capital of China". After nearly two decades of stable development, Yuanlun Valve is a professional manufacturer for HVAC valves integrating R&D, production and sales. Our product portfolio covers floor heating systems, air-conditioning systems, domestic water valves, including ball valves, thermostatic valves, manifolds, check valves, stop valves, filter valves, angle valves, pipe fittings, corrugated pipes and other series.

 

Hot Tags: mf manual angle aluminum-plastic pipe radiator valve, China mf manual angle aluminum-plastic pipe radiator valve manufacturers, suppliers, factory, MF Manual Radiator Valve

Send Inquiry
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!