Drain Valve
The Dirt Problem in Every Fluid System
Every pipeline, tank, and vessel that carries water, steam, or process fluid accumulates unwanted material over time:
- Sediment - sand, scale, rust particles carried in from the water source
- Sludge - biological growth, corrosion by-products, accumulated debris
- Condensate - water that forms when steam cools in piping
- Oil/water mixtures - in compressed air systems and hydraulic circuits
- Settled solids - heavy particles that settle at low points in the system
If this material is not removed regularly, it causes:
- Reduced system efficiency - sediment insulates heat transfer surfaces
- Equipment damage - sludge accelerates corrosion and wears pumps
- Flow restriction - accumulated debris blocks pipes and valves
- Contamination - settled solids re-suspend and contaminate downstream processes
The drain valve is the simple, manual solution. Installed at the lowest point of the system, it allows operators to periodically open the valve and flush out accumulated sediment, sludge, and condensate.
Our Yuanlun brass drain valve is designed for this exact purpose - manual, reliable removal of unwanted material from the bottom of piping systems, tanks, and vessels in HVAC, plumbing, boiler, compressor, and industrial applications.
| Feature | Without Drain Valve | With Drain Valve (This Model) |
|---|---|---|
| Sediment removal | None – accumulates | Manual flush – easy removal |
| System efficiency | Degrades over time | Maintained – clean system |
| Equipment life | Shortened by corrosion/sludge | Extended – clean operation |
Product Introduction
The Yuanlun Brass Drain & Pressure Relief Valve combines two core functions: pipeline draining and automatic overpressure protection. As an integrated safety fitting for piping and pressure vessel systems, this valve automatically opens once internal pressure exceeds the pre-set threshold, discharging surplus fluid to lower system pressure and prevent pipe cracking, equipment deformation or burst caused by overpressure.
With a compact brass body, fast response and flexible configuration, this dual-purpose drain and pressure relief valve is widely deployed in HVAC heating systems, water supply & drainage networks, industrial fluid transfer lines and gas control assemblies. It serves as an essential safety component to stabilize operating pressure and protect the whole pipeline system.
Core Technical Advantages
-
Manual Operation - Simple, Reliable, No Power Required
The valve is operated by hand - no electricity, no compressed air, no control system. This makes it inherently reliable for its intended purpose: periodic manual draining.
-
Full-Port Drainage - Quick, Unrestricted Flow
The valve provides a full, unrestricted flow path when open, allowing sediment, sludge, and debris to pass through without clogging. This is essential for removing solids, not just clean fluid.
-
Corrosion-Resistant Brass Body
The forged brass body resists corrosion from water, condensate, and mild chemical exposure. It provides long service life in HVAC, plumbing, and industrial applications.
-
Durable Sealing - Leak-Tight in Closed Position
The disc and seat are precision-machined with an O-ring or face seal. When closed, the valve holds system pressure without leakage - no drips, no weeping.
-
Easy Maintenance
The valve has a simple, robust design with few moving parts. Seal replacement is straightforward and can be performed without removing the valve from the line (on most models).
-
Multiple Seal Options for Media Compatibility
- NBR - water, air, oil up to 120°C
- FKM - hot water, steam, aggressive fluids up to 200°C
- PTFE - chemical resistance with appropriate body


Technical Specifications
| Item | Specification |
|---|---|
|
Place of origin |
China |
|
Brand name |
Yunnl |
|
Product Name |
Drain Valve |
| Body Material | Brass |
| Seal Material | Nitrile Rubber (NBR), Fluorocarbon Rubber (FKM), Polytetrafluoroethylene (PTFE) |
| Pressure Range | Set Pressure: 0.05 MPa – 2.5 MPa (adjustable) Max. Working Pressure: ≤1.1 × set pressure |
| Temperature Range | Standard: ‑10 °C to 120 °C High‑temp (special seals): ≤200 °C |
| Connection Type | G½″ |
| Suitable Media | Water, steam, compressed air, hydraulic oil, inert gases, etc. (material‑dependent) |
| Certifications | ISO 4126 (safety valve general requirements), ASME I/VIII (pressure equipment) Optional: CE‑PED, TSG (special equipment safety technical code) |
|
Minimum Order Quantity |
1 |
|
Price |
Negotiable |
|
Packing |
Yunnl standard packing |
|
Payment Terms |
L/C, D/A, D/P, T/T, Western Union,MoneyGram |
|
Delivery Time |
15 Days |
Drain Valve vs. Blowdown Valve vs. Sediment Drain: Clarifying the Terms
| Term | Meaning | Typical Use |
|---|---|---|
| Drain Valve | General term for fluid removal | System draining, tank emptying |
| Blowdown Valve | Sediment/sludge removal under pressure | Boiler blowdown, compressor receiver drain |
| Sediment Drain | Solids removal from bottom of vessels | Tank bottom drains, pipeline low-point drains |
| Condensate Drain | Water removal from steam/air systems | Steam trap drains, air receiver drains |
Our valve serves all of these functions -a single valve design for manual removal of unwanted material from the bottom of fluid systems.
Working Principle: Manual Operation
-
Pressure Monitoring Phase
System pressure acts on the valve core or diaphragm via the inlet. When pressure is below the set value, a spring or gravity mechanism keeps the valve closed.
-
Automatic Relief Phase
When pressure rises to the set threshold, it overcomes the spring preload (or diaphragm resistance), moving the core. The seal opens, directing fluid through the discharge port to a safe area (e.g., drain pipe or recovery unit).
-
Pressure Recovery & Closing
As fluid is discharged, system pressure gradually drops to a safe range. The spring returns the core to its seat, resealing the port and restoring the closed state.
-
Adjustability
Rotating the adjustment screw changes the spring preload, allowing different relief set points. Some models include a manual test lever for routine functional checks.
FQA
Q: What is the difference between a drain valve and a relief valve?
A: A drain valve is manual – it is opened by hand to remove sediment, condensate, or fluid. A relief valve is automatic – it opens on its own when system pressure exceeds a set point to prevent overpressure. They serve completely different functions.
Q: Where should I install a drain valve?
A: At the lowest point of the pipeline, tank, or vessel. Sediment and condensate collect at the bottom, so the drain valve must be positioned there to remove them effectively.
Q: How often should I open the drain valve?
A: Frequency depends on the system. Daily for compressed air receivers and boiler blowdown; weekly or monthly for clean water systems; as needed for tank draining. If the discharged fluid is dirty, increase the frequency.
Q: Does the valve seal completely when closed?
A: Yes. When closed, the disc seals against the seat, preventing leakage under rated working pressure.
Q: Can I leave the valve partially open to drain continuously?
A: Not recommended. The valve is designed for full open/full closed service. Partial opening can cause seat erosion and accelerate wear.
Q: Do you offer samples?
A: Yes. Minimum order quantity is 1 unit. Sample orders are welcome for quality and dimension verification.
Q: What is the maximum working pressure?
A: PN16 (1.6 MPa / 16 bar). Please specify if your system requires higher pressure.
Hot Tags: drain valve, China drain valve manufacturers, suppliers, factory, Underfloor Heating Bypass Valve, Underfloor heating angle ball valve, Exhaust valve component, Floor Heating Angle Ball Valve