Exhaust Valve Assembly

Exhaust Valve Assembly

Details
Place of origin: China
Brand name: Yunnl
Product Name:Exhaust valve assembly
Size:DN25-DN32
Minimum Order Quantity: 0
Price: Negotiable
Packing:Yunnl standard packing
Payment Terms: L/C, D/A, D/P, T/T, Western Union,MoneyGram
Delivery Time:15 Days
Applicable temperature: 5℃ to 90℃
Category
Floor Heating Accessories
 
Send Inquiry
Description
Technical Parameters

Exhaust Valve Assembly

 

Three Problems, One Valve

Every closed-loop heating system suffers from the same three enemies:

Enemy 1: Trapped Air

  • Air accumulates at high points
  • Blocks water flow → cold radiators
  • Causes pump cavitation → noise and damage
  • Reduces heat transfer → wasted energy

Enemy 2: Stagnant Water

  • Water needs to be drained for maintenance
  • No drain point → messy pipe disconnection
  • Time-consuming and risky

Enemy 3: Sludge and Sediment

  • Rust, scale, and debris collect over time
  • Accumulates at low points
  • Clogs pipes and valves
  • Reduces system efficiency

The conventional solution: Install three separate components:

  1. An air vent at the high point
  2. A drain valve at the low point
  3. A blowdown valve for sludge removal

The better solution: One component does all three jobs.

3 Separate Components This 3‑in‑1 Valve
3 components to buy 1 component
3 installation points 1 installation point
6+ threaded connections 2 connections
3 maintenance schedules 1 maintenance point
More leak points Fewer leak points
More space required Compact

 

Introduction

Our brass 3‑in‑1 automatic air vent valve is an all‑in‑one pipeline fitting engineered for closed‑loop hot‑water heating circuits, widely deployed in underfloor heating, radiators and central heating systems for residential and commercial projects.

Manufactured from hot‑forged high‑grade brass, the valve undergoes electroplating and baking‑paint dual‑surface finishing for superior corrosion resistance. It consolidates three core pipeline functions within one compact body: automatic air venting, manual pipeline draining and sludge blowdown.

Designed with an enlarged air‑collecting chamber, double locking caps and wear‑resistant conical O‑ring seals, this unit delivers fast air purging, straightforward on‑site installation and reliable long‑term leak‑free performance. Rated PN16 (1.6 MPa), it fits DN25 and DN32 pipe connections, and operates reliably across 5 °C‑90 °C circulating water temperature range.

 

Three Functions Explained

Function 1: Automatic Air Venting (Float‑Operated)

The air vent uses a simple, reliable float mechanism:

Stage Action
Air accumulation Air enters the chamber, displacing water
Float drops Water level falls, float sinks
Vent opens Float opens the vent port
Air discharges Trapped air escapes
Water returns Water refills the chamber
Float rises Float seals the vent port
Vent closes No water leakage

Key design feature: The enlarged air chamber holds more air, allowing faster venting during system startup.

Function 2: Manual Drainage

When the system needs to be drained for maintenance or repairs:

  1. Open the drain valve manually
  2. Water flows out through the drain port
  3. Close the valve after drainage

Why this matters: Without a drain point, maintenance requires disconnecting pipes-messy, time‑consuming, and risky.

Function 3: Sludge Blowdown

Over time, sediment and sludge collect at low points:

  1. Open the blowdown port
  2. System pressure flushes out accumulated sludge
  3. Close the port when water runs clear

Why this matters: Sludge reduces efficiency and damages components. Regular flushing keeps the system clean.

 

How Air Affects Your Heating System

Symptom Cause Consequences
Cold spots on radiators Air trapped at top Reduced heat output
Gurgling noises Air moving in pipes Disturbing noise
Pump noise/vibration Cavitation from air Pump damage
Slow heating Air blocking flow Longer warm‑up times
Corrosion Oxygen in trapped air System damage

The automatic air vent removes air continuously, eliminating these problems without manual intervention.

 

Core Advantages

  • Multi‑Function Combined Unit

This single fitting merges three separate capabilities: automatic air release, water draining, and sediment blow‑off. Consolidating these features into one unit minimises the total number of parts within your circuit, streamlines overall system layout and shortens on‑site assembly hours.

  • Durable Stainless‑Steel Float Assembly

Built with stainless‑steel float instead of common plastic alternatives. It avoids water absorption, shape distortion and gradual loss of buoyancy triggered by long‑term hot‑water exposure. Consistent functional performance can be maintained throughout the whole service cycle of heating installations.

  • Expanded Air Chamber for Rapid Degassing

Its generously sized inner air cavity can accommodate larger air volumes. This enables much quicker air purging while heating circuits start‑up, shortening waiting periods before the heating system reaches its full working output.

  • Tapered EPDM Sealing for Bubble‑Tight Shut‑off

Adopting conical‑profile EPDM sealing element delivers multiple benefits:

  1. Superior sealing performance under varying working pressure
  2. Extended service lifespan of sealing components
  3. Stable performance against repeated temperature fluctuations
  • High‑Quality Forged Brass Build

Manufactured from HPb59‑1 forged brass, finished with electroplating plus baking‑paint surface treatment:

  1. Excellent corrosion resistance adapted for hot‑water heating loops
  2. Zero internal void or porosity inside valve body
  3. Outstanding long‑term durability

Manual Intervention Top Cap

The top access cap supports manual opening for multiple on‑site scenarios:

  1. Emergency air releasing operations
  2. Complete system flushing work
  3. Convenient entry point for routine inspection and servicing
a92422ba-cef2-4b9d-ba5d-6e49728eda03
26ecb46f-0245-46e6-8dc2-3e43b4d56818
ssss
w
dddd
ss
Specifications
Feature Description

Place of origin

China

Brand name

Yunnl

Product Name

Exhaust Valve Assembly
Main Material Brass
Nominal Working Pressure PN16 (1.6MPa)
Working Medium Temperature 5℃ ~ 90℃ Hot Water

Size

DN25-DN32

Core Functions Automatic Air Venting, Manual Drainage, Sludge Blowdown
Sealing Component Wear-resistant Conical Rubber O-Ring

Minimum Order Quantity

1

Price

Negotiable

Packing

Yunnl standard packing

Payment Terms

L/C, D/A, D/P, T/T, Western Union,MoneyGram

Delivery Time

15 Days

 

Market & Application Benefits

  • Broad System Compatibility

Works seamlessly with underfloor heating, wall‑mounted radiators and boiler circulation systems. Especially ideal for high‑rise apartments and large commercial premises prone to heavy air accumulation.

  • Low‑Cost Long‑Term Maintenance

Robust simple float‑based internal mechanism delivers low failure rates. Routine visual inspection is sufficient to keep the valve working, lowering ongoing operating expenses.

  • Enhanced Heating‑System Reliability

Continuous automatic air venting prevents air‑binding. This avoids reduced heating output, pipeline knocking noise and premature damage to circulation pumps.

  • Optimised Total Cost of Ownership

The unified multi‑function design removes the requirement to source separate air vents and drain valves. It lowers procurement costs and cuts material expenses compared to traditional multi‑component pipeline setups.

 

How the Automatic Air Vent Operates

Air pockets commonly build up at elevated sections within heating pipework. As trapped gas collects inside the valve housing, the water level inside falls accordingly. This movement lowers the integrated float component, which uncovers the exhaust opening to let trapped air escape without manual intervention.

Once all trapped air has been expelled, process water fills the valve housing again. The rising water level pushes the float upward, sealing the exhaust opening tightly to prevent any water from spilling out under normal working pressure.

Apart from fully‑automatic air release, this unit comes with a manual override function. By rotating the top locking cap, operators can carry out forced air bleeding. This feature also enables sludge and stagnant water drainage during routine servicing or unexpected blockage scenarios.

Installation position is critical for proper performance. This air vent must be mounted at the highest elevation of the heating circuit. Its working principle depends on natural buoyancy, which allows air bubbles to travel upward into the valve chamber for effective degassing.

 

Installation & Troubleshooting Guide

  • Installation Recommendations

  1. Mount the valve on the highest position of heating pipelines to collect upward‑moving air.
  2. Avoid over‑tightening threaded connections to prevent cracking brass threads.
  3. Keep sufficient clearance around the top manual cap for future inspection and maintenance work.
  • Common Troubleshooting

  1. Slow venting performance: Remove the cap and clean sludge deposits inside the air chamber.
  2. Minor dripping after air release: Replace worn‑out conical O‑ring sealing components.
  3. Float stuck / malfunction: Flush internal cavity thoroughly to clear pipeline sediment and debris.

 

Application Scenarios

  • Residential Underfloor Heating Circuits

Application: Mounted at the elevated positions within underfloor heating piping loops.

Benefit: Releases trapped air generated at system commissioning, effectively eliminating uneven heating and cold zones across floor surfaces.

  • Radiator‑Based Heating Installations

Application: Fitted onto the top‑most radiator or designated high‑elevation points of heating circuits.

Benefit: Resolves air‑lock issues, a common root cause for radiators failing to reach full operating temperature.

  • Boiler‑Driven Heating Units

Application: Positioned on boiler outlet manifolds or the system's highest elevation locations.

Benefit: Discharges accumulated air from high‑temperature sections of the heating circuit to stabilise system performance.

  • Commercial HVAC Heating Networks

Application: Deployed at peak elevation points throughout large‑scale commercial heating piping networks.

Benefit: Delivers ongoing automatic air purging for multi‑floor facilities and divided thermal zones.

  • High‑Rise Plumbing & Heating Infrastructure

Application: Equipped on the upper section of every vertical riser pipe.

Benefit: Air tends to gather at riser peaks in tall buildings; distributed air vents guarantee reliable de‑aeration for the whole building.

  • Solar Thermal Heating Circuits

Application: Mounted at the highest spot of solar collector assemblies.

Benefit: Expels trapped air building up inside collector pipelines to maintain consistent heat transfer efficiency.

 

FQA

Q: Where should I mount this 3‑in‑1 exhaust valve?

A: Always install it at the highest point of your closed‑loop heating pipeline. Air rises naturally, so high‑point mounting ensures maximum air‑capture efficiency. Mounting at lower positions will greatly reduce venting performance.

Q: Can this valve work for chilled‑water cooling systems?

A: It is optimised for hot‑water heating circuits within 5‑90°C. For chilled‑water cooling applications, please confirm working temperature and medium before ordering.

Q: Why does slight dripping happen after venting?

A: Dripping mostly comes from aged or contaminated O‑ring seals. Disassemble the cap, clean sealing surfaces, or replace the conical O‑ring to restore zero‑leak performance.

Q: Do I still need separate drain and blowdown valves after fitting this unit?

A: No. This all‑in‑one unit integrates air vent, manual drain and sludge blowdown, replacing three separate standard valves for most heating‑system projects.

Q: What maintenance is required for long‑term operation?

A: Conduct annual inspection. Open the locking cap to flush sludge and sediment inside the air chamber, and check O‑ring condition. Regular cleaning prevents float jamming and slow venting.

 

 

Hot Tags: exhaust valve assembly, China exhaust valve assembly manufacturers, suppliers, factory, Underfloor Heating Bypass Valve, Underfloor heating angle ball valve, Exhaust valve component, Floor Heating Angle Ball Valve

Send Inquiry
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!