Support Bracket

Support Bracket

Details
Place of origin: China
Brand name: Yunnl
Product Name:Support bracket
Size:DN25.DN32
Minimum Order Quantity: 0
Price: Negotiable
Packing:Yunnl standard packing
Payment Terms: L/C, D/A, D/P, T/T, Western Union,MoneyGram
Delivery Time:15 Days
Applicable temperature: 5℃ to 90℃
Category
Floor Heating Accessories
 
Send Inquiry
Description
Technical Parameters

Support Bracket

 

The Hidden Cost of an Unstable Manifold

The manifold is the heart of an underfloor heating system. It distributes hot water to every heating loop in the building. But when the manifold is not properly secured, problems emerge:

Vibration damage – Water flow creates constant vibration. Over months and years, this vibration:

  • Loosens threaded connections → leaks develop
  • Wears pipe joints → premature failure
  • Transfers noise to the building structure → occupant complaints

Thermal movement – Heating pipes expand and contract with temperature changes. This movement:

  • Shifts the manifold out of alignment
  • Stresses pipe connections
  • Creates tension at joints → leak points

Water hammer – Sudden valve closures create shockwaves. These shocks:

  • Jolt the manifold
  • Transmit force to pipe connections
  • Accelerate wear on seals and threads

A properly designed support bracket eliminates these problems. It holds the manifold firmly in place, absorbs vibration, accommodates thermal movement, and protects against shock loads.

Unsecured Manifold Secured with This Bracket
Vibrates → loosens connections Vibration absorbed by rubber pads
Shifts with thermal expansion Long slots accommodate movement
Water hammer shocks the manifold Rigid frame absorbs shock
Leaks develop over time Leak‑free operation
Premature system failure 10+ year service life

 

Introduction

Our manifold support bracket is purpose‑built to securely fasten supply and return manifolds within underfloor heating systems.

During long‑term heating cycles, water‑flow vibration, thermal expansion and water hammer can make manifolds shift, tilt or rattle. This heavy‑duty mounting bracket eliminates those unwanted movements. By holding manifolds in stable position, it safeguards the entire heating pipeline assembly and extends the service life of pipe thread connections.

 

Core Product Features & Technical Advantages

  • Heavy‑Duty Anti‑Corrosion Material

Two material options are available: SS304 stainless steel, SS316 stainless steel, and hot‑dip galvanized carbon steel.

Every bracket completes minimum 500‑hour neutral salt‑spray testing. It delivers reliable rust resistance for coastal humid sites, industrial corrosive surroundings and outdoor agricultural installations, delivering stable performance for over 10 years.

  • Reinforced Anti‑Vibration Construction

The dual‑column high‑load frame, ribbed base plate and triangular reinforcing structure deliver high overall load‑bearing capacity. Integrated rubber shock‑absorbing pads effectively damp pipeline vibration.

Adjustable long slots accommodate thermal expansion deformation, keeping manifolds perfectly level without tilting. Validated under 10‑bar pulse water pressure and cyclic temperature from 5℃ to 85℃, mounting precision stays within ±1 mm throughout its service lifespan.

  • Dual‑Mode Flexible Installation

Designed for both wall‑mount and floor‑mount fitting. Compatible with standard expansion bolts and common fasteners. Installers can freely adjust layout to match real‑world pipeline layouts on underfloor heating job sites.

  • Pipeline Leak Risk Reduction

It restricts manifold shaking and displacement while systems run. Less movement lowers friction wear on threaded pipe joints, greatly cutting potential risks of pipeline leakage and unexpected system failures.

 

product-1-1

 

1

 

Specifications

Feature Description

Place of origin

China

Brand name

Yunnl

Product Name

Support Bracket
Size DN25,DN32
Available Material SS304 Stainless Steel / SS316 Stainless Steel / Hot-dip Galvanized Steel
Salt Spray Resistance ≥500 Hours
Working Temperature Range 5℃ ~ 90℃
Test Pulse Pressure 10 Bar
Service Life ≥10 Years
Mounting Type Wall Mount / Floor Mount

Minimum Order Quantity

1

Price

Negotiable

Packing

Yunnl standard packing

Payment Terms

L/C, D/A, D/P, T/T, Western Union,MoneyGram

Delivery Time

15 Days

 

Application Scenarios

  • Residential Underfloor Heating

Use case: Securing manifolds in single‑family homes and apartments.
Value: Prevents vibration noise, maintains balanced flow to all heating loops.

  • Commercial Building Heating

Use case: Multi‑zone heating in apartments, hotels, and offices.
Value: Reliable fixation for multiple manifolds in plant rooms.

  • Coastal & Marine Environments

Use case: Seaside buildings and marine applications.
Value: SS316 stainless steel resists saltwater corrosion.

  • Industrial Heating Systems

Use case: Factory floor heating, warehouse heating.
Value: Heavy‑duty construction withstands industrial conditions.

  • Outdoor Agricultural Heating

Use case: Greenhouse heating, agricultural facility heating.
Value: Galvanized or stainless options resist outdoor exposure.

  • Heating System Renovation

Use case: Replacing old, corroded brackets in existing systems.
Value: Easy retrofit, eliminates vibration and leakage issues.

 

Installation Guide

  • Pre‑Installation

  1. Select mounting location – Choose a flat, solid wall or floor surface near the manifold
  2. Verify load capacity – Confirm the surface can support the weight of the bracket + manifold (full of water)
  3. Choose mounting type – Wall mount (vertical) or floor mount (horizontal)
  • Wall Mount Installation

  1. Mark hole positions – Use the bracket as a template
  2. Drill holes – Use appropriate drill bit for wall material (concrete, brick, or stud)
  3. Insert anchors – Use expansion anchors suitable for the wall type
  4. Mount the bracket – Secure with expansion screws, do not fully tighten
  5. Place the manifold – Position the supply and return manifolds in the bracket
  6. Adjust level – Use a spirit level, adjust as needed
  7. Tighten all fasteners – Secure bracket to wall, secure manifold to bracket
  • Floor Mount Installation

  1. Position the bracket – Place on the floor at the desired location
  2. Mark hole positions – Use the bracket base as a template
  3. Drill and anchor – Secure to the concrete floor with expansion bolts
  4. Place the manifold – Position manifolds in the rubber clamping slots
  5. Adjust and tighten – Level the manifold, tighten all fasteners
  • Post‑Installation Check

  1. Verify the manifold is level (check with spirit level)
  2. Apply slight force to the manifold-it should not move or shift
  3. Ensure the bracket is firmly attached to the wall or floor
  4. Check that rubber pads are in contact with the manifold
  5. Leave clearance around pipe connections for future maintenance

 

FQA

Q: Which manifold sizes does this support bracket fit?

A: Standard models fit DN25 and DN32 underfloor heating manifolds. Custom sizes are available upon request for special project requirements.

Q: Can I use galvanized carbon‑steel brackets in coastal seaside projects?

A: Hot‑dip galvanized versions work for general coastal conditions. For high‑salt‑air seaside sites, SS316 stainless steel is strongly recommended for better long‑term anti‑corrosion performance.

Q: Is special hardware required for installation?

A: No special parts are needed. The bracket works with standard industry expansion screws and common fasteners available on construction sites.

Q: Can this bracket fix vibration‑caused manifold leaks?

A: It prevents new leaks by stopping manifold shaking and joint friction wear. If existing thread connections are already damaged, replace fittings before fitting the bracket.

Q: Can it be used for renovation of old heating systems?

A: Yes. It is widely applied in retrofit jobs. Remove old worn‑out brackets and install this unit to stabilize manifolds and reduce recurring vibration issues.

 

 

Hot Tags: support bracket, China support bracket manufacturers, suppliers, factory, Underfloor Heating Bypass Valve, Underfloor heating angle ball valve, Exhaust valve component, Floor Heating Angle Ball Valve

Send Inquiry
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!