Floor Heating Bypass Valve

Floor Heating Bypass Valve

Details
Place of origin: China
Brand name: Yunnl
Product Name:Floor heating bypass valve
Size:DN20-DN50
Minimum Order Quantity: 0
Price: Negotiable
Packing:Yunnl standard packing
Payment Terms: L/C, D/A, D/P, T/T, Western Union,MoneyGram
Delivery Time:15 Days
Applicable temperature: 5℃ to 90℃
Category
Floor Heating Accessories
 
Send Inquiry
Description
Technical Parameters

Floor Heating Bypass Valve

 

Introduction

The Yuanlun floor heating bypass valve is a hydraulic self-acting differential pressure bypass valve for underfloor heating systems. It senses supply-return pressure difference and automatically opens a bypass passage when pressure exceeds the set value (0.05-0.15 MPa), diverting excess flow back to the return line.

Hot-forged from HPb58-2 brass with a spring-diaphragm mechanism, it requires no external power supply. Available in DN20-DN50, rated PN16, with a working temperature range of 5℃-95℃. It stabilizes system pressure, protects circulation pumps and wall-hung boilers, prevents pump overheating and boiler short-cycling, and reduces energy consumption by 10%-20% in field tests.

 

Key Advantages

  • Hot-Forged HPb58-2 Brass Body

Dense, porosity-free structure. Shell tested at 2.4 MPa (ISO 5208), rated PN16 (1.6 MPa). Available DN20-DN50 for residential to commercial heating projects.

  • Water Hammer Buffer & Component Protection

Cushions hydraulic shocks, reduces pressure fluctuations. Prevents circulation pump overheating and boiler short-cycling under low-flow conditions, extending equipment service life.

  • Energy Savings & Hydraulic Balance

Automatically bypasses excess flow, reducing ineffective circulation. Field tests show 10%-20% lower pump power consumption. Maintains uniform heating across all floor heating circuits.

  • All-Mechanical, Maintenance-Free

Spring-diaphragm hydraulic structure, no electronics or power supply. Natural brass body resists oxidation. No routine maintenance needed after installation and commissioning.

 

product-1-1

Technical Specifications

Item Specification
Body Material Brass
Actuation Type Hydraulic self‑acting (spring‑diaphragm), no power required
Pressure Adjustment Range Start differential pressure: 0.05–0.15 MPa (adjustable)
Max. working pressure: ≤1.0 MPa
Temperature Range Medium temperature: 5 °C–95 °C
Ambient temperature: –10 °C–60 °C
Connection Sizes Common sizes: DN20–DN50
Flow Coefficient (Kv) Approx. 2–6 m³/h (depending on size and differential pressure)
Optional Features Field‑adjustable differential pressure, integrated temperature sensor, bypass status indicator
Suitable Media Water, glycol‑water solutions (≤40% concentration), and other non‑corrosive heat‑transfer fluids
Certifications Complies with EN 215 (thermostatic valves) and ISO 5208 (valve testing) requirements

 

Working Principle

  1. Pressure Sensing: Connected between supply and return lines. The spring-diaphragm mechanism continuously monitors the pressure difference.
  2. Automatic Bypass Opening: When differential pressure exceeds the set value (0.05-0.15 MPa), the diaphragm moves the valve core to open the bypass passage, diverting part of the flow back to the return line.
  3. System Balance Restoration: As bypass flow increases, total system resistance drops, restoring differential pressure below the set range. The spring returns the valve core, gradually closing the bypass.
  4. Low-Temperature Protection (Optional): Some models integrate a temperature sensor that increases bypass flow when return-water temperature is too low, preventing boiler condensation corrosion.

 

Precautions

  1. Install between the supply and return lines, as close to the circulation pump as possible.
  2. Set the differential pressure according to system design requirements (typically 0.05-0.15 MPa).
  3. Do not exceed max working pressure of 1.0 MPa or medium temperature of 95℃.
  4. Clean the pipeline before installation to remove debris that could damage the diaphragm.
  5. For glycol-water solutions, ensure concentration does not exceed 40%.
  6. The valve is maintenance-free under normal operating conditions; inspect annually for signs of seepage.

 

FQA

Q: Does this bypass valve require electricity?

A: No. It is fully hydraulic self-acting with a spring-diaphragm mechanism. No external power supply or electronics are needed.

Q: How do I adjust the differential pressure setting?

A: The top adjustment knob allows field adjustment of the start differential pressure within 0.05-0.15 MPa. Refer to the scale on the valve body.

Q: What size should I choose for my system?

A: Select based on system flow rate and pipe diameter. DN20-DN25 for residential systems, DN32-DN50 for commercial or large residential projects. The Kv value ranges from 2 to 6 m³/h depending on size.

Q: Can this valve be used with glycol antifreeze solutions?

A: Yes, it is compatible with glycol-water solutions up to 40% concentration, as well as water and other non-corrosive heat-transfer fluids.

Q: What is the difference between this and a manual bypass valve?

A: This valve automatically adjusts bypass flow based on real-time differential pressure, maintaining hydraulic balance without manual intervention. A manual bypass valve requires manual adjustment and cannot respond to system changes dynamically.

Q: Do you accept OEM?

A: Yes, we accept OEM and ODM orders, including custom branding, packaging and pressure ranges.

 

 

Hot Tags: floor heating bypass valve, China floor heating bypass valve manufacturers, suppliers, factory, Underfloor Heating Bypass Valve, Underfloor heating angle ball valve, Exhaust valve component, Floor Heating Angle Ball Valve

Send Inquiry
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!